Back to Search Start Over

[Translated article] A 3D method to estimate the effect of derotational osteotomies over femoral maltorsion.

Authors :
Ferràs-Tarragó J
Sanchis-Alfonso V
Ramírez-Fuentes C
Roselló-Añón A
Elía-Martínez I
Source :
Revista espanola de cirugia ortopedica y traumatologia [Rev Esp Cir Ortop Traumatol] 2022 Nov-Dec; Vol. 66 (6), pp. T36-T42. Date of Electronic Publication: 2022 Jul 17.
Publication Year :
2022

Abstract

Introduction and Objectives: Accurate measurement of femoral torsion is essential to diagnosing, correct surgical decision-making, and the preoperative planning of derotational osteotomies in a subgroup of anterior knee pain patients and patellofemoral instability. Several measurement techniques have been described with great variability in the magnitude of the values. Moreover, none of them can predict the effect of rotational osteotomy on the femoral version value. The purpose of the present work is to develop a method to reliably measure femoral torsion as well as to evaluate the effects of osteotomy on the femoral version angle.<br />Material and Methods: 30 patients without previous signs neither symptoms of patellofemoral pain or patellofemoral instability and with a lower limbs CT were selected. Their femoral torsion was measured using the classic Jeanmart and the Murphy's method by two independent radiologists. Independently, two orthopedic surgeons measured femoral torsion with the 3D method described in this study. The intraclass coefficient correlation and the Bland-Altman tests were used to analyze qualitatively and quantitatively the intraobserver and interobserver variability of the method regarding the Jeanmart's and Murphy's method. The confidence interval of the Normal values of the new method were defined and a lineal regression analysis between the 3D-Jeanmart's and 3D-Muphy's methods was performed.<br />Results: The mean femoral version with the 3D method was 12.74° (SD 5.96°, 95% CI: 11.67°-13.82°). With Jeanmart's method, it was 12.84° (SD 8.60°, 95% CI: 11.28°-14.39°) and 15.87° (SD 10.68°, 95% CI: 13.94°-17.80°) with Murphy's method, being these differences not statistically significant. Both interobserver and intraobserver agreement of the 3D method were high.<br />Conclusion: The method presented in this study allows for the reliable quantification of femoral torsion in a reproducible way. This method can be applied in several open access 3D image programmes what makes its implementation in the healthcare centres possible from now on.<br /> (Copyright © 2022 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.)

Details

Language :
English; Spanish; Castilian
ISSN :
1988-8856
Volume :
66
Issue :
6
Database :
MEDLINE
Journal :
Revista espanola de cirugia ortopedica y traumatologia
Publication Type :
Academic Journal
Accession number :
35858671
Full Text :
https://doi.org/10.1016/j.recot.2022.07.016