Back to Search Start Over

Segmented 3D Echo Planar Acquisition for Rapid Susceptibility-Weighted Imaging: Application to Microhemorrhage Detection in Traumatic Brain Injury.

Authors :
Wang WT
Li N
Papageorgiou I
Chan L
Pham DL
Butman JA
Source :
Journal of magnetic resonance imaging : JMRI [J Magn Reson Imaging] 2022 Nov; Vol. 56 (5), pp. 1529-1535. Date of Electronic Publication: 2022 Jul 19.
Publication Year :
2022

Abstract

Background: Susceptibility-weighted imaging (SWI) provides superior image contrast of cerebral microhemorrhages (CMBs). It is based on a three-dimensional (3D) gradient echo (GRE) sequence with a relatively long imaging time.<br />Purpose: To evaluate whether an accelerated 3D segmented echo planar imaging SWI is comparable to GRE SWI in detecting CMBs in traumatic brain injury (TBI).<br />Study Type: Prospective.<br />Subjects: Four healthy volunteers and 46 consecutive subjects (38.0 ± 14.4 years, 16 females; 12 mild, 13 moderate, and 7 severe TBI).<br />Field Strength/sequence: A 3 T scanner/3D gradient echo and 3D segmented echo planar imaging (segEPI).<br />Assessment: Brain images were acquired using GRE and segEPI in a single session (imaging time = 9 minutes 47 seconds and 1 minute 30 seconds, respectively). The signal-to-noise ratio (SNR) calculated from healthy volunteer thalamus and centrum semiovale were compared. CMBs were counted by three raters blinded to diagnostic information.<br />Statistical Tests: A t-test was used to assess SNR difference. Pearson correlation and Wilcoxon signed-rank test were performed using CMB counts. The intermethod agreement was evaluated using Bland-Altman method. Intermethod and interrater reliabilities of image-based diffuse axonal injury (DAI) diagnoses were evaluated using Cohen's kappa and percent agreement. P ≤ 0.05 was considered statistically significant.<br />Results: Thalamus SNRs were 16.9 ± 2.2 and 16.5 ± 3 for GRE and segEPI (P = 0.84), respectively. Centrum semiovale SNRs were 25.8 ± 4.6 and 21.1 ± 2.7 (P = 0.13). The correlation coefficient of CMBs was 0.93, and differences were not significant (P = 0.56-0.85). For DAI diagnoses, Cohen's kappa was 0.62-0.84 and percent agreement was 85%-94%.<br />Data Conclusion: CMB counts on segEPI and GRE were highly correlated, and DAI diagnosis was made equally effectively. segEPI SWI can potentially replace GRE SWI in detecting TBI CMBs, especially when time constraints are critical.<br />Evidence Level: 1 TECHNICAL EFFICACY: Stage 2.<br /> (Published 2022. This article is a U.S. Government work and is in the public domain in the USA. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)

Details

Language :
English
ISSN :
1522-2586
Volume :
56
Issue :
5
Database :
MEDLINE
Journal :
Journal of magnetic resonance imaging : JMRI
Publication Type :
Academic Journal
Accession number :
35852491
Full Text :
https://doi.org/10.1002/jmri.28326