Back to Search Start Over

[Diagnostic value of a novel test paper detection of ECP in nasal secretion for allergic rhinitis].

Authors :
Li H
Xi Y
Chen J
Chen J
Deng Y
Tao Z
Source :
Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery [Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi] 2022 Jun; Vol. 36 (6), pp. 407-413.
Publication Year :
2022

Abstract

Objective: To explore the diagnostic value of a novel test paper, which detect eosinophil cationic protein(ECP) of nasal secretion in allergic rhinitis(AR). Methods: Nasal secretion and serum samples from 107 patients with allergic rhinitis(AR group) and 40 healthy volunteers(control group) were selected. The nasal symptoms were also evaluated in AR group. The degree of ECP coloration was evaluated by nasal secretion eosinophil cationic protein-myeloperoxid(ECP-MPO) test paper, and the concentration of ECP in nasal secretion and the concentration of cytokines in serum were detected at the same time. The difference and correlation among these indexes were analyzed. The best cutoff value and test efficiency of ECP chromogenic grade and concentration of nasal secretion were calculated by receiver operating characteristic curve(ROC). Results: The concentration of ECP in nasal secretion of AR patients was significantly higher than that of healthy controls( P <0.05). The color grade of nasal secretion detected by the test paper was positively correlated with the concentration of ECP in nasal secretion( P <0.05), and there was significant difference among different grades( P <0.05). There was a satisfying symmetry between the ECP color grade of nasal secretion and the serum specific IgE(sIgE) level as well as a high diagnostic consistency between them( P <0.05). The area under the curve(AUC) of ECP concentration ROC in nasal secretion was 0.807 2, corresponding to 64% sensitivity and 85% specificity when the cutoff value was set at 0.980 5; when the cutoff value was set at 1, the AUC of nasal secretion ECP color grading was 0.941 9, corresponding to 92% sensitivity and 94% specificity. No clear correlation between the concentration of ECP in nasal secretion and serum cytokines was found( P >0.05). Conclusion: The results of this novel test paper is in good agreement with those of serological allergens. It could serve as a preliminary test to evaluate the severity of allergy with satisfactory sensitivity and specificity, and is especially suitable in clinical practice for primary hospital.<br />Competing Interests: The authors of this article and the planning committee members and staff have no relevant financial relationships with commercial interests to disclose.<br /> (Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.)

Details

Language :
Chinese
ISSN :
2096-7993
Volume :
36
Issue :
6
Database :
MEDLINE
Journal :
Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology, head, and neck surgery
Publication Type :
Academic Journal
Accession number :
35822356
Full Text :
https://doi.org/10.13201/j.issn.2096-7993.2022.06.001