Back to Search
Start Over
Combined assessment by transcranial sonography and Sniffin' Sticks test has a similar diagnostic accuracy compared to brain SPECT for Parkinson's disease diagnosis.
- Source :
-
Clinical neurology and neurosurgery [Clin Neurol Neurosurg] 2022 Sep; Vol. 220, pp. 107333. Date of Electronic Publication: 2022 Jun 11. - Publication Year :
- 2022
-
Abstract
- Objectives: This study aimed to investigate the accuracy of TCS combined with the Sniffin' sticks olfactory test (SST-16) for differentiation between idiopathic PD patients and healthy controls compared to that of <superscript>99 m</superscript> Tc-TRODAT-1 SPECT (TRODAT).<br />Methods: A cross-sectional study included PD patients diagnosed in accordance with United Kingdom PD Society Brain Bank criteria and a control group of age and sex- matched healthy subjects. All patients were examined by a movement disorder specialist and underwent brain SPECT using TRODAT, TCS examination and SST-16 test. Receiver Operating Characteristic (ROC) curves were used to calculate cut-off points for TCS, striatal TRODAT binding potentials and SST-16. The area under the ROC curve determined the diagnostic accuracy of the method.<br />Results: Twenty patients with PD (13 males and 7 females) and nine healthy subjects were included. Median age of PD onset was 56.5 years with median disease duration of 5 years. A larger substantia nigra (SN) echogenic area was observed in the PD group (p = 0.013). SN echogenic area cut-off point of 0.22 cm <superscript>2</superscript> was obtained from a ROC curve for PD diagnosis. Considering this cut-off point, TCS diagnostic accuracy was estimated at 79.2% for PD diagnosis. The cut-off value of 0.90 for striatal TRODAT binding was associated with 99% diagnostic accuracy for the diagnosis of PD. SST-16 values equal or less than 9 points showed an 85.8% diagnostic accuracy for PD diagnosis. Combination of both SST-16 and TCS improved the diagnostic accuracy to 95% for PD diagnosis.<br />Conclusion: Combined SST-16 and TCS assessment was indicated as accurate for distinguishing PD patients from healthy controls. The diagnostic accuracy of TCS combined with SST-16 for differentiation between idiopathic PD patients and healthy controls is similar to that of SPECT TRODAT.<br />Competing Interests: Declarations of interest None.<br /> (Copyright © 2022 Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1872-6968
- Volume :
- 220
- Database :
- MEDLINE
- Journal :
- Clinical neurology and neurosurgery
- Publication Type :
- Academic Journal
- Accession number :
- 35816824
- Full Text :
- https://doi.org/10.1016/j.clineuro.2022.107333