Back to Search Start Over

Radiostrontium clearance and bone formation in response to simulated internal screw fixation.

Authors :
Daum WJ
Simmons DJ
Fenster R
Shively RA
Source :
Clinical orthopaedics and related research [Clin Orthop Relat Res] 1987 Jun (219), pp. 283-90.
Publication Year :
1987

Abstract

Changes in radiostrontium clearance (SrC) and bone formation (tetracycline labeling) were observed in the femurs of skeletally mature dogs following the various operative steps involved in bone screw fixation. Drilling, but not periosteal stripping, produced a small but statistically significant increase in SrC and endosteal bone formation in the distal third of the bone. Strontium clearance values equivalent to those produced by drilling alone were recorded after screw fixation at low or high torque (5 versus 20 inch pounds), as well as by the insertion of loosely fitting stainless steel implants. Bone formation (equals the percentage tetracycline-labeled trabecular bone surfaces) was increased by 30% when SrC values exceeded 3.5 ml/100 g bone/min, and the relationship was linear when SrC values ranged between 1.0 and 7.0 ml/100 g bone/min. The changes in SrC and bone formation one-week after bone screw application are primarily those associated with a response to local trauma caused by drilling.

Details

Language :
English
ISSN :
0009-921X
Issue :
219
Database :
MEDLINE
Journal :
Clinical orthopaedics and related research
Publication Type :
Academic Journal
Accession number :
3581581