Back to Search Start Over

Use of biochemical parameters for non-invasive screening of oesophageal varices in comparison to elastography-based approach in patients with compensated advanced chronic liver disease.

Authors :
Pastrovic F
Madir A
Podrug K
Lucijanic M
Bokun T
Zelenika M
Mustapic S
Unic A
Derek L
Grgurevic I
Source :
Biochemia medica [Biochem Med (Zagreb)] 2022 Jun 15; Vol. 32 (2), pp. 020712.
Publication Year :
2022

Abstract

Introduction: Oesophageal varices are routinely diagnosed by esophagogastroduodenoscopy (EGD), and their bleeding has high mortality. We aimed to evaluate diagnostic performance of biochemical tests in comparison to elastography-based approaches, as non-invasive alternatives to EGD, for ruling-out high risk oesophageal varices (HRV).<br />Material and Methods: Retrospective analysis of patients (N = 861) who underwent liver stiffness measurement (LSM) by transient elastography (TE) in a single centre over 5-year period, with available results of EGD (within 3 months from LSM). Only patients with suspicion of compensated advanced chronic liver disease (cACLD) defined by LSM ≥ 10 kPa were included comprising the final cohort of 73 subjects. Original and expanded Baveno VI criteria (B6C), controlled attenuation parameter (CAP), platelet count (PLT), aspartate aminotransferase to PLT ratio index (APRI), Fibrosis-4 index (FIB4), model for end stage liver disease (MELD) score were evaluated against the results of EGD that served as the reference method.<br />Results: Analysed patients had median age 62 years, 59/73 (0.81) were males, 54/73 (0.74) had alcoholic/non-alcoholic fatty liver disease, and 21/73 (0.29) had HRV. In multivariate logistic regression analysis only LSM and PLT were independently associated with HRV. The best performing tests for ruling-out HRV (% of spared EGD; % of missed HRV) were respectively: LSM < 20 kPa (53.4%; 0%), B6C (38%; 0%), Expanded B6C (47.9%; 4.8%); PLT > 214x10 <superscript>9</superscript> /L (21.9%; 0%); FIB4 ≤ 1.8 (21.4%; 0%), APRI ≤ 0.34 (12.3%; 0%). CAP, MELD = 6 alone or combined with PLT > 150(x10 <superscript>9</superscript> /L) did not show acceptable performance.<br />Conclusion: The best performing biochemical tests for ruling-out HRV in our cohort of patients were PLT and FIB-4, but they were still outperformed by elastography-based approaches.<br />Competing Interests: Potential conflict of interest None declared.<br /> (Croatian Society of Medical Biochemistry and Laboratory Medicine.)

Details

Language :
English
ISSN :
1846-7482
Volume :
32
Issue :
2
Database :
MEDLINE
Journal :
Biochemia medica
Publication Type :
Academic Journal
Accession number :
35799983
Full Text :
https://doi.org/10.11613/BM.2022.020712