Back to Search Start Over

Association of robot-assisted techniques with the accuracy rates of pedicle screw placement: A network pooling analysis.

Authors :
Wei FL
Gao QY
Heng W
Zhu KL
Yang F
Du RM
Zhou CP
Qian JX
Yan XD
Source :
EClinicalMedicine [EClinicalMedicine] 2022 Jun 09; Vol. 48, pp. 101421. Date of Electronic Publication: 2022 Jun 09 (Print Publication: 2022).
Publication Year :
2022

Abstract

Background: Traditional paired meta-analyses have yielded inconsistent results for the safety and effectiveness of robotic-assisted pedicle screw placement due to the high heterogeneity within studies. This study evaluated the clinical effectiveness and safety of robotic-assisted pedicle screw placement.<br />Methods: The Embase, PubMed, and Cochrane Library databases were searched with no language limitations from inception to Jan 4, 2022. Odds ratio (OR), mean difference (MD), and 95% confidence interval (CI) were used to report results. The main outcomes were accuracy of pedicle screw placement, proximal facet joint violation, and complications. The study protocol was published in PROSPERO (CRD42022301417).<br />Findings: 26 trials including 2046 participants evaluating robotic-assisted pedicle screw placement were included in this study. Our pooled results showed that Renaissance (OR 2.86; [95% CI 1.79 to 4.57]) and TiRobot (OR 3.10; [95% CI 2.19 to 4.40]) yielded higher rates of perfect pedicle screw insertion (Grades A) than the conventional freehand technique. Renaissance (OR 2.82; [95% CI 1.51 to 5.25]) and TiRobot (OR 4.58; [95% CI 2.65 to 7.89]) yielded higher rates of clinically acceptable pedicle screw insertion (Grades A+B). However, ROSA, SpineAssist, and Orthobot were not associated with higher perfect pedicle screw insertion and clinically acceptable pedicle screw insertion rates. Robot-assisted techniques were associated with low rates of proximal facet joint violation (OR 0.18; [95% CI 0.10 to 0.32]; I <superscript>2</superscript> :9.55%) and overall complications (OR 0.38; [95% CI 0.23 to 0.63]; I <superscript>2</superscript> :27.05%). Moreover, robot-assisted techniques were associated with lower radiation doses (MD -14.38; [95% CI -25.62 to -3.13]; I <superscript>2</superscript> :100.00%).<br />Interpretation: Our findings suggest that only Renaissance and TiRobot systems are associated with high accuracy rates of pedicle screw placement. Robotic-assisted techniques hold great promise in spinal surgery due to their safety and effectiveness.<br />Funding: This work was supported by grants from the National Natural Science Foundation of China (No. 81871818), Tangdu Hospital Seed Talent Program (Fei-Long Wei) and Natural Science Basic Research Plan in Shaanxi Province of China (No.2019JM-265).<br />Competing Interests: We declare no competing interests.<br /> (© 2022 The Authors.)

Details

Language :
English
ISSN :
2589-5370
Volume :
48
Database :
MEDLINE
Journal :
EClinicalMedicine
Publication Type :
Academic Journal
Accession number :
35706496
Full Text :
https://doi.org/10.1016/j.eclinm.2022.101421