Back to Search Start Over

Effects of different stent wire mesh densities on hemodynamics in aneurysms of different sizes.

Authors :
Masuda S
Fujimura S
Takao H
Takeshita K
Suzuki T
Uchiyama Y
Karagiozov K
Ishibashi T
Fukudome K
Yamamoto M
Murayama Y
Source :
PloS one [PLoS One] 2022 Jun 10; Vol. 17 (6), pp. e0269675. Date of Electronic Publication: 2022 Jun 10 (Print Publication: 2022).
Publication Year :
2022

Abstract

Background: Intracranial stents are used to treat aneurysms by diverting the blood flow from entering into the aneurysmal dome. Although delayed rupture is rare, clinical outcomes are extremely poor in such cases. Hemodynamics after stent deployment may be related to delayed rupture and a better understanding of the basic characteristics of pressure changes resulting from stent deployment is needed; therefore, this study investigated the relationships between hemodynamics in aneurysms of different sizes treated using stents of different wire mesh densities.<br />Methods: Using computational fluid dynamics analysis, parameters related to velocity, volume flow rate, pressure, and residual volume inside the aneurysm were evaluated in digital models of 5 basic aneurysms of differing sizes (Small, Medium, Medium-Large, Large, and Giant) and using 6 different types of stent (varying number of wires, stent pitch and wire mesh density) for each aneurysm.<br />Results: Regardless of the aneurysm size, the velocity inside the aneurysm and the volume flow rate into the aneurysm were observed to continuously decrease up to 89.2% and 78.1%, respectively, with increasing stent mesh density. In terms of pressure, for giant aneurysms, the pressure on the aneurysmal surface elevated to 10.3%, then decreased to 5.1% with increasing stent mesh density. However, in smaller aneurysms, this pressure continuously decreased with increasing stent mesh density. The flow-diverting effect of the stents was limited when a stent with low mesh density (under 20%) was used with a giant aneurysm.<br />Conclusions: The present results indicate that the selection of appropriate stents according to aneurysm size may contribute to reduced risks of hemodynamic alternations related to stent deployment, which could reduce the incidence of delayed rupture.<br />Competing Interests: T. Suzuki is full-time employee of Siemens Healthcare and S. Masuda is full-time employees of Cybernet System Co., Ltd. This does not alter our adherence to PLOS ONE policies on sharing data and materials.

Details

Language :
English
ISSN :
1932-6203
Volume :
17
Issue :
6
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
35687558
Full Text :
https://doi.org/10.1371/journal.pone.0269675