Back to Search Start Over

Systematic review, meta-analysis and single-centre experience of the diagnostic accuracy of intraoperative near-infrared indocyanine green-fluorescence in detecting pancreatic tumours.

Authors :
Rompianesi G
Montalti R
Giglio MC
Ceresa CDL
Nasto RA
De Simone G
Troisi RI
Source :
HPB : the official journal of the International Hepato Pancreato Biliary Association [HPB (Oxford)] 2022 Nov; Vol. 24 (11), pp. 1823-1831. Date of Electronic Publication: 2022 May 16.
Publication Year :
2022

Abstract

Background: During pancreatic resections assessing tumour boundaries and identifying the ideal resection margins can be challenging due to the associated pancreatic gland inflammation and texture. This is particularly true in the context of minimally invasive surgery, where there is a very limited or absent tactile feedback. Indocyanine green (ICG) fluorescence imaging can assist surgeons by simply providing valuable real-time intraoperative information at low cost with minimal side effects. This meta-analysis summarises the available evidence on the use of near-infrared fluorescence imaging with ICG for the intraoperative visualization of pancreatic tumours (PROSPERO ID: CRD42021247203).<br />Methods: MEDLINE, Embase, and Web Of Science electronic databases were searched to identify manuscripts where ICG was intravenously administered prior to or during pancreatic surgery and reporting the prevalence of pancreatic lesions visualised through fluorescence imaging.<br />Results: Six studies with 7 series' reporting data on 64 pancreatic lesions were included in the analysis. MINOR scores ranged from 6 to 10, with a median of 8. The most frequent indications were pancreatic adenocarcinoma and neuroendocrine tumours. In most cases (67.2%) ICG was administered during surgery. ICG fluorescence identified 48/64 lesions (75%) with 81.3% accuracy, 0.788 (95%CI 0.361-0.961) sensitivity, 1 (95%CI 0.072-1) specificity and positive predictive value of 0.982 (95%CI 0.532-1). In line with the literature, ICG fluorescence identified 5/6 (83.3%) of pancreatic lesions during robotic pancreatic resections performed at our Institution.<br />Conclusion: This meta-analysis is the first summarising the results of ICG immunofluorescence in detecting pancreatic tumours during surgery, showing good accuracy. Additional research is needed to define optimal ICG administration strategies and fluorescence intensity cut-offs.<br /> (Copyright © 2022 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1477-2574
Volume :
24
Issue :
11
Database :
MEDLINE
Journal :
HPB : the official journal of the International Hepato Pancreato Biliary Association
Publication Type :
Academic Journal
Accession number :
35654671
Full Text :
https://doi.org/10.1016/j.hpb.2022.05.004