Automatic Registration and Error Color Maps to Improve Accuracy for Navigated Bone Tumor Surgery Using Intraoperative Cone-Beam CT.

Authors :
Sahovaler A
Daly MJ
Chan HHL
Nayak P
Tzelnick S
Arkhangorodsky M
Qiu J
Weersink R
Irish JC
Ferguson P
Wunder JS
Source :
JB & JS open access [JB JS Open Access] 2022 May 05; Vol. 7 (2). Date of Electronic Publication: 2022 May 05 (Print Publication: 2022).
Publication Year :
2022

Abstract

Computer-assisted surgery (CAS) can improve surgical precision in orthopaedic oncology. Accurate alignment of the patient's imaging coordinates with the anatomy, known as registration, is one of the most challenging aspects of CAS and can be associated with substantial error. Using intraoperative, on-the-table, cone-beam computed tomography (CBCT), we performed a pilot clinical study to validate a method for automatic intraoperative registration.<br />Methods: Patients who were ≥18 years of age, had benign bone tumors, and underwent resection were prospectively enrolled. In addition to inserting a navigation tracking tool into the exposed bone adjacent to the surgical field, 2 custom plastic ULTEM tracking tools (UTTs) were attached to each patient's skin adjacent to the tumor using an adhesive. These were automatically localized within the 3-dimensional CBCT volume to be used as image landmarks for registration, and the corresponding tracker landmarks were captured using an infrared camera. The main outcomes were the fiducial registration error (FRE) and the target registration error (TRE). The navigation time was recorded.<br />Results: Thirteen patients with benign tumors in the femur (n = 10), tibia (n = 2), and humerus (n = 1) underwent navigation-assisted resections. The mean values were 0.67 ± 0.15 mm (range, 0.47 to 0.97 mm) for FRE and 0.83 ± 0.51 mm (range, 0.42 to 2.28 mm) for TRE. Registration was successful in all cases. The mean time for CBCT imaging and tracker registration was 7.5 minutes.<br />Conclusions: We present a novel automatic registration method for CAS exploiting intraoperative CBCT capabilities, which provided improved accuracy and reduced operative times compared with more traditional methods.<br />Clinical Relevance: This proof-of-principle study validated a novel process for automatic registration to improve the accuracy of resecting bone tumors using a surgical navigation system.<br />Competing Interests: Disclosure: The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSOA/A386).<br /> (Copyright © 2022 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved.)

Details

Language :
English
ISSN :
2472-7245
Volume :
7
Issue :
2
Database :
MEDLINE
Journal :
JB & JS open access
Publication Type :
Academic Journal
Accession number :
35540727
Full Text :
https://doi.org/10.2106/JBJS.OA.21.00140