Back to Search Start Over

Diagnostic Performance of CT-Derived Fractional Flow Reserve in Australian Patients Referred for Invasive Coronary Angiography.

Authors :
Chua A
Ihdayhid AR
Linde JJ
Sørgaard M
Cameron JD
Seneviratne SK
Ko BS
Source :
Heart, lung & circulation [Heart Lung Circ] 2022 Aug; Vol. 31 (8), pp. 1102-1109. Date of Electronic Publication: 2022 Apr 29.
Publication Year :
2022

Abstract

Background: Non-invasive computed tomography (CT)-derived fractional flow reserve (FFR <subscript>CT</subscript> ) is computed from standard coronary CT angiography (CTA) datasets and provides accurate vessel-specific ischaemia assessment of coronary artery disease (CAD). To date, the technique and its diagnostic performance has not been verified in the Australian clinical context. The aim of this study was to describe and compare the diagnostic performance of FFR <subscript>CT</subscript> and CTA for the detection of vessel-specific ischaemia as determined by invasive fractional flow reserve (FFR) in the Australian patient population.<br />Methods: One-hundred-and-nine patients (219 vessels) referred for clinically mandated invasive angiography were retrospectively assessed. Each patient underwent research mandated CTA and FFR <subscript>CT</subscript> within 3 months of invasive angiography and invasive FFR assessment. Independent core laboratory assessments were made to determine visual CTA stenosis, FFR <subscript>CT</subscript> and invasive FFR values. FFR <subscript>CT</subscript> values were matched with the corresponding invasive FFR measurement taken at the given wire position. Visual CTA stenosis ≥50%, FFR <subscript>CT</subscript> values ≤0.8 and invasive FFR values ≤0.8 were considered significant for ischaemia.<br />Results: Per vessel accuracy, sensitivity, specificity, positive predictive value and negative predictive value of FFR <subscript>CT</subscript> were 80.4%, 80.0%, 80.6%, 64.9% and 90.0% respectively. Corresponding values for CTA were 75.1%, 87.1%, 69.2%, 58.1% and 91.7% respectively. In receiver operating characteristic curve analysis, FFR <subscript>CT</subscript> demonstrated superior area under the curve (AUC) compared with CTA in both per vessel (0.87 vs 0.77, p=0.004) and per patient analysis (0.86 vs 0.74, p=0.011). Per vessel AUC of combined CTA and FFR <subscript>CT</subscript> was superior to CTA alone (0.89 vs 0.77, p<0.0001).<br />Conclusion: In this cohort of Australian patients, the diagnostic performance of FFR <subscript>CT</subscript> was found to be comparable to existing international literature, with demonstrated improvement in performance compared with CTA alone for the detection of vessel-specific ischaemia.<br /> (Copyright © 2022 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1444-2892
Volume :
31
Issue :
8
Database :
MEDLINE
Journal :
Heart, lung & circulation
Publication Type :
Academic Journal
Accession number :
35501246
Full Text :
https://doi.org/10.1016/j.hlc.2022.03.008