Back to Search Start Over

Six Percent Incidence of Graft-Tunnel Mismatch in Anatomic Anterior Cruciate Ligament Reconstruction Using Bone-Patella Tendon-Bone Autograft and Anteromedial Portal Drilling.

Authors :
Dwyer T
Hoit G
Sellan M
Gopinath R
Whelan D
Theodoropoulos J
Chahal J
Source :
Arthroscopy, sports medicine, and rehabilitation [Arthrosc Sports Med Rehabil] 2021 Dec 08; Vol. 4 (2), pp. e479-e486. Date of Electronic Publication: 2021 Dec 08 (Print Publication: 2022).
Publication Year :
2021

Abstract

Purpose: The purpose of this study was to determine the incidence of graft-tunnel mismatch (GTM) when performing anatomic anterior cruciate ligament reconstruction (ACLR) using bone-patella tendon-bone (BPTB) grafts and anteromedial portal drilling.<br />Methods: Beginning in November 2018, 100 consecutive patients who underwent ACLR by two sports fellowship-trained, orthopedic surgeons using BPTB autograft and anteromedial portal drilling were prospectively identified. The BPTB graft dimensions and the femoral tunnel distance, tibial tunnel distance, intra-articular distance, and total distance were measured. Surgeons determined the depth and angle of tunnels based on the patella tendon graft length dimensions in each case. After passage of the graft, the distance from the distal graft tip to the tibial cortex aperture was measured. GTM was defined as the need for additional measures to obtain satisfactory tibial graft fixation (<15-20 mm of bone fixation).<br />Results: The incidence of mismatch was 6/100 (6%). Five cases involved the graft being too long, with the tibial bone plug protruding excessively from the tibial tunnel-4/5 had a patella tendon length ≥ 50 mm. Three cases were managed with femoral tunnel recession, and two were treated with a free bone plug technique. One patient with a patella tendon length of 35 mm had a graft that was too short, with the tibial bone plug recessed in the tibial tunnel. Of patients whose tibial tunnel distance was within 5 mm of the patella tendon length, only 1/46 (2%) patients had mismatch, whereas 5/54 (9%) of patients who had >5 mm difference had mismatch.<br />Conclusions: The incidence of graft-tunnel mismatch after anatomic ACLR using BTPB and anteromedial portal drilling in this study is 6%. To limit the occurrence of GTM where the graft is too long, surgeons should drill tibial tunnel distances within 5 mm of the patella tendon length.<br />Clinical Relevance: The results of this study provide surgeons with a technique of limiting graft tunnel mismatch when performing ACLR using BPTB and anteromedial portal drilling.<br /> (© 2021 The Authors.)

Details

Language :
English
ISSN :
2666-061X
Volume :
4
Issue :
2
Database :
MEDLINE
Journal :
Arthroscopy, sports medicine, and rehabilitation
Publication Type :
Academic Journal
Accession number :
35494272
Full Text :
https://doi.org/10.1016/j.asmr.2021.11.006