Back to Search Start Over

Impact of acceleration on bone depiction quality by ultrashort echo time magnetic resonance bone imaging sequences in medication-related osteonecrosis of the jaw.

Authors :
Getzmann JM
Huber FA
Nakhostin D
Deininger-Czermak E
Schumann P
Finkenstaedt T
Del Grande F
Guggenberger R
Source :
European journal of radiology open [Eur J Radiol Open] 2022 Apr 23; Vol. 9, pp. 100421. Date of Electronic Publication: 2022 Apr 23 (Print Publication: 2022).
Publication Year :
2022

Abstract

Objectives: To assess the impact on bone depiction quality by decreasing number of radial acquisitions (RA) of a UTE MR bone imaging sequence in MRONJ.<br />Material and Methods: UTE MR bone imaging sequences using pointwise encoding time reduction with RA (PETRA) with 60'000, 30'000 and 10'000 RA were acquired in 16 patients with MRONJ and 16 healthy volunteers. Blinded readout sessions were performed by two radiologists. Qualitative analysis compared the detection of osteolytic lesions and productive bony changes in the PETRA sequences of the patients with MRONJ. Quantitative analysis assessed the differences in image artifacts, contrast-to-noise ratio (CNR) and image noise.<br />Results: Acquisition times were reduced from 315 to 165 and 65 s (60'000, 30'000, 10'000 RA, respectively), resulting in a fewer number of severe motion artifacts. Bone delineation was increasingly blurred when reducing the number of RA but without any trade-off in terms of diagnostic performance. Interreader agreement for the detection of pathognomonic osteolysis was moderate (κ = 0.538) for 60'000 RA and decreased to fair (κ = 0.227 and κ = 0.390) when comparing 30'000 and 10'000 RA, respectively. Image quality between sequences was comparable regarding CNR, image noise and artifact dimensions without significant differences (all P  > 0.05).<br />Conclusions: UTE MR bone imaging sequences with a lower number of RA provide sufficient image quality for detecting osteolytic lesions and productive bony changes in MRONJ subjects at faster acquisition times compared to the respective standard UTE MR bone imaging sequence.<br />Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (© 2022 The Authors.)

Details

Language :
English
ISSN :
2352-0477
Volume :
9
Database :
MEDLINE
Journal :
European journal of radiology open
Publication Type :
Academic Journal
Accession number :
35494189
Full Text :