Back to Search
Start Over
Inferior mesenteric artery diameter and number of patent lumbar arteries as factors associated with significant type 2 endoleak after infrarenal endovascular aneurysm repair.
- Source :
-
Interactive cardiovascular and thoracic surgery [Interact Cardiovasc Thorac Surg] 2022 Jun 15; Vol. 35 (1). - Publication Year :
- 2022
-
Abstract
- Objectives: Our goal was to identify the inferior mesenteric artery diameter and number of patent lumbar arteries causing a significant type 2 endoleak to develop after infrarenal endovascular aneurysm repair.<br />Material and Methods: Included were patients who underwent infrarenal endovascular aneurysm repair between April 2002 and January 2017. Patients with an aneurysm involving the iliac arteries were excluded. Significant type 2 endoleak was defined as a type 2 endoleak observed after infrarenal endovascular aneurysm repair and accompanied by abdominal aneurysm growth of at least 5 mm during that time.<br />Results: A total of 277 patients were included. Mean follow-up was 38.9 (standard deviation 121.6) months. Immediately after infrarenal endovascular aneurysm repair, type 2 endoleaks occurred in 55 patients (20%), resolving spontaneously in 2 patients 6 months after infrarenal endovascular aneurysm repair. Thirty (10.8%) patients revealed a significant type 2 endoleak with aneurysm sack enlargement > 5 mm during follow-up, for which inferior mesenteric artery or lumbar artery coiling was performed. Mean time for coiling after primary infrarenal endovascular aneurysm repair was 25.4 (standard deviation 19.10) months. Twenty-three patients (8.3%) showed a non-significant type 2 endoleak during follow-up (no aneurysm sack enlargement). We found that the inferior mesenteric artery diameter and number of patent lumbar arteries were factors associated with a significant type 2 endoleak (odds ratio 1.755, P = 0.001; odds ratio 1.717, P < 0.001, respectively). Prior to endovascular aneurysm repair, the inferior mesenteric artery was patent in 212 (76.5%) patients; its median diameter measured 3 (0.5-3.8) mm. The median number of patent lumbar arteries was 3 (2-4). According to our receiver operating characteristic curve analysis, an inferior mesenteric artery diameter ≥3 mm (sensitivity 93.3%, specificity 65%) and ≥3 patent lumbar arteries (sensitivity 87.5%, specificity 43.6%) proved to be optimal cut-off values related to developing a significant type 2 endoleak. We therefore propose a composite score for the development of a significant type 2 endoleak [(inferior mesenteric artery diameter + patent lumbar arteries)/2].<br />Conclusions: Patients in whom the diameter of the inferior mesenteric artery is ≥ 3 mm and with ≥ 3 patent lumbar arteries carry a higher risk of developing significant type 2 endoleak after infrarenal endovascular aneurysm repair.<br /> (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.)
- Subjects :
- Endoleak diagnostic imaging
Endoleak etiology
Humans
Mesenteric Artery, Inferior diagnostic imaging
Retrospective Studies
Risk Factors
Treatment Outcome
Aortic Aneurysm, Abdominal complications
Aortic Aneurysm, Abdominal diagnostic imaging
Aortic Aneurysm, Abdominal surgery
Blood Vessel Prosthesis Implantation adverse effects
Endovascular Procedures adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1569-9285
- Volume :
- 35
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Interactive cardiovascular and thoracic surgery
- Publication Type :
- Academic Journal
- Accession number :
- 35425973
- Full Text :
- https://doi.org/10.1093/icvts/ivac016