Rapid detection of influenza virus by shell vial assay with monoclonal antibodies.
- Source :
-
Journal of clinical microbiology [J Clin Microbiol] 1986 Oct; Vol. 24 (4), pp. 677-9. - Publication Year :
- 1986
-
Abstract
- Of 45 influenza virus strains (43 type A and 2 type B) detected in conventional tube cell cultures (average time, 4 days), 25 (56%) were detected by immunofluorescence in the shell vial assay 24 h postinoculation. The specific fluorescence produced should allow this procedure to be readily adapted by laboratories with various degrees of experience with immunofluorescence methodology.
Details
- Language :
- English
- ISSN :
- 0095-1137
- Volume :
- 24
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Journal of clinical microbiology
- Publication Type :
- Academic Journal
- Accession number :
- 3533980
- Full Text :
- https://doi.org/10.1128/jcm.24.4.677-679.1986