Back to Search
Start Over
Diagnostic Accuracy of Coronary Angiography-Based Vessel Fractional Flow Reserve (vFFR) Virtual Stenting.
- Source :
-
Journal of clinical medicine [J Clin Med] 2022 Mar 03; Vol. 11 (5). Date of Electronic Publication: 2022 Mar 03. - Publication Year :
- 2022
-
Abstract
- 3D coronary angiography-based vessel fractional flow reserve (vFFR) proved to be an accurate diagnostic alternative to invasively measured pressure wire based fractional flow reserve (FFR). The ability to compute post-PCI vFFR using pre-PCI vFFR virtual stent analysis is unknown. We aimed to assess the feasibility and diagnostic accuracy of pre-PCI vFFR virtual stenting analysis (residual vFFR) with post-PCI FFR as a reference. This is an observational, single-center retrospective cohort study including consecutive patients from the FFR-SEARCH registry. We blindly calculated residual vFFR from pre-PCI angiograms and compared them to invasive pressure-wire based post-PCI FFR. Inclusion criteria involved presentation with either stable or unstable angina or non-ST elevation myocardial infarction (NSTEMI), ≥1 significant stenosis in one of the epicardial coronary arteries (percentage diameter stenosis of >70% by QCA or hemodynamically relevant stenosis with FFR ≤0.80) and pre procedural angiograms eligible for vFFR analysis. Exclusion criteria comprised patients with ST elevation myocardial infarction (STEMI), coronary bypass grafts, cardiogenic shock or severe hemodynamic instability. Eighty-one pre-PCI residual vFFR measurements were compared to post-PCI FFR and post-PCI vFFR measurements. Mean residual vFFR was 0.91 ± 0.06, mean post-PCI FFR 0.91 ± 0.06 and mean post-PCI vFFR was 0.92 ± 0.05. Residual vFFR showed a high linear correlation (r = 0.84) and good agreement (mean difference (95% confidence interval): 0.005 (−0.002−0.012)) with post-PCI FFR, as well as with post-PCI-vFFR (r = 0.77, mean difference −0.007 (−0.015−0.0003)). Residual vFFR showed good accuracy in the identification of lesions with post-PCI FFR < 0.90 (sensitivity 94%, specificity 71%, area under the curve (AUC) 0.93 (95% CI: 0.86−0.99), p < 0.001). Virtual stenting using vFFR provided an accurate estimation of post-PCI FFR and post-PCI vFFR. Further studies are needed to prospectively validate a vFFR-guided PCI strategy.
Details
- Language :
- English
- ISSN :
- 2077-0383
- Volume :
- 11
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Journal of clinical medicine
- Publication Type :
- Academic Journal
- Accession number :
- 35268488
- Full Text :
- https://doi.org/10.3390/jcm11051397