Quantitative MR-Neurography at 3.0T: Inter-Scanner Reproducibility.

Authors :
Preisner F
Behnisch R
Schwehr V
Godel T
Schwarz D
Foesleitner O
Bäumer P
Heiland S
Bendszus M
Kronlage M
Source :
Frontiers in neuroscience [Front Neurosci] 2022 Feb 16; Vol. 16, pp. 817316. Date of Electronic Publication: 2022 Feb 16 (Print Publication: 2022).
Publication Year :
2022

Abstract

Background: Quantitative MR-neurography (MRN) is increasingly applied, however, the impact of the MR-scanner on the derived parameters is unknown. Here, we used different 3.0T MR scanners and applied comparable MR-sequences in order to quantify the inter-scanner reproducibility of various MRN parameters of the sciatic nerve.<br />Methods: Ten healthy volunteers were prospectively examined at three different 3.0T MR scanners and underwent MRN of their sciatic nerve using comparable imaging protocols including diffusion tensor imaging (DTI) and T2 relaxometry. Subsequently, inter-scanner agreement was assessed for seven different parameters by calculating the intraclass correlation coefficients (ICCs) and the standard error of measurement (SEM).<br />Results: Assessment of inter-scanner reliability revealed good to excellent agreement for T2 (ICC: 0.846) and the quantitative DTI parameters, such as fractional anisotropy (FA) (ICC: 0.876), whereas moderate agreement was observed for proton spin density (PD) (ICC: 0.51). Analysis of variance identified significant inter-scanner differences for several parameters, such as FA ( p < 0.001; p = 0.02), T2 ( p < 0.01) and PD ( p = 0.02; p < 0.01; p = 0.02). Calculated SEM values were mostly within the range of one standard deviation of the absolute mean values, for example 0.033 for FA, 4.12 ms for T2 and 27.8 for PD.<br />Conclusion: This study quantifies the measurement imprecision for peripheral nerve DTI and T2 relaxometry, which is associated with the use of different MR scanners. The here presented values may serve as an orientation of the possible scanner-associated fluctuations of MRN biomarkers, which can occur under similar conditions.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2022 Preisner, Behnisch, Schwehr, Godel, Schwarz, Foesleitner, Bäumer, Heiland, Bendszus and Kronlage.)

Details

Language :
English
ISSN :
1662-4548
Volume :
16
Database :
MEDLINE
Journal :
Frontiers in neuroscience
Publication Type :
Academic Journal
Accession number :
35250457
Full Text :
https://doi.org/10.3389/fnins.2022.817316