Back to Search Start Over

Mid-term outcomes of the use of endoanchors during thoracic endovascular aortic repair in multicentre analysis.

Authors :
Reyes Valdivia A
Milner R
Heijmen R
Riambau V
Rousseau H
Tinelli G
Kotelis D
Zanabili Al-Sibbai AA
Pitoulias G
Zúñiga CG
de Beaufort HWL
Panagiotis D
Chaudhuri A
Source :
Vascular [Vascular] 2023 Jun; Vol. 31 (3), pp. 455-462. Date of Electronic Publication: 2022 Feb 27.
Publication Year :
2023

Abstract

Objective: To describe mid-term outcomes of the use of EndoAnchors as an adjunct for arch and thoracic endovascular aortic repair (TEVAR).<br />Methods: A retrospective multicentre series from nine centres using the Heli-FX EndoAnchor System (Medtronic Inc, Minneapolis, USA) at TEVAR over May 2014-May 2019 is presented. The study is registered at ClinicalTrials.gov with number NCT04100499. The primary outcome was freedom from Type I endoleak at EndoAnchors deployments; secondary outcomes included evaluation of aortic wall penetration (AWP) at first computed tomography scan, EndoAnchor-related issues and mortality.<br />Results: 54 high-risk patients (35 males/19 females, age 73 ± 11 years) with arch, thoracic and thoracoabdominal aneurysmal disease (3 chronic post-dissection and one patch pseudoaneurysm), with a mean neck length 19.7 ± 6.6 mm that were treated with multiple hybrid and endovascular techniques were included. A total of 329 EndoAnchors were used with a mean of 6.1 ± 2.5 per patient. Overall adequate AWP was 86%, whereas arch (Ishimaru's zones 0-2) deployments achieved 80.6% when compared to 87.3% in descending thoracic aorta (dTA); although there was no statistical significance. Freedom from type I endoleaks was 88% at 2 year follow-up, due to 4 type IA endoleaks, two of them successfully treated, one with conservative treatment due to complexity of repair and remaining patient died 1 year later due to endograft infection. There were reported five EndoAnchor-related issues; four losses and one renal stent-graft was crushed due to catheter deflection solved with balloon reinflation. None of the losses had clinical significance. Overall mortality is described for 7 (9.5%) patients, one of them aneurysm-related.<br />Conclusions: The adjunctive use of EndoAnchors in TEVAR and complex TEVAR procedures achieved acceptable outcomes at midterm in a high-risk series with hostile seal zones. Still, they should be still judiciously used as there is lack of data to suggest a more liberal use; therefore, the landing zone should not be compromised in favour of their use.

Details

Language :
English
ISSN :
1708-539X
Volume :
31
Issue :
3
Database :
MEDLINE
Journal :
Vascular
Publication Type :
Academic Journal
Accession number :
35225085
Full Text :
https://doi.org/10.1177/17085381221076320