Back to Search
Start Over
Diaphragmatic CMAP Monitoring During Cryoballoon Procedures: Surface vs. Hepatic Recording Comparison and Limitations of This Approach.
- Source :
-
Frontiers in cardiovascular medicine [Front Cardiovasc Med] 2022 Feb 08; Vol. 9, pp. 814026. Date of Electronic Publication: 2022 Feb 08 (Print Publication: 2022). - Publication Year :
- 2022
-
Abstract
- Background: Compound motor action potential (CMAP) monitoring is a common method used to prevent right phrenic nerve palsy during cryoballoon ablation for atrial fibrillation.<br />Objective: We compared recordings simultaneously obtained with surface and hepatic electrodes.<br />Methods: We included 114 consecutive patients (mean age 61.7 ± 10.9 years) admitted to our department for cryoballoon ablation. CMAP was monitored simultaneously with a hepatic catheter and a modified lead I ECG, whilst right phrenic nerve was paced before (stage 1) and during (stage 2) the right-sided freezes. If phrenic threat was detected with hepatic recordings (CMAP amplitude drop >30%) the application was discontinued with forced deflation.<br />Results: The ratio of CMAP/QRS was 4.63 (2.67-9.46) for hepatic and 0.76 (0.55-1.14) for surface ( p < 0.0001). Signal coefficients of variation during stage 1 were 3.92% (2.48-6.74) and 4.10% (2.85-5.96) ( p = 0.2177), respectively. Uninterpretable signals were more frequent on surface (median 10 vs. 0; p < 0.0001). For the 14 phrenic threats, the CMAP amplitude dropped by 35.61 ± 8.27% on hepatic signal and by 33.42 ± 11.58% concomitantly on surface ( p = 0.5417). Our main limitation was to achieve to obtain stable phrenic capture (57%). CMAP monitoring was not reliable because of pacing instability in 15 patients (13.16%). A palsy occurred in 4 patients (3.51%) because cryoapplication was halted too late.<br />Conclusion: Both methods are feasible with the same signal stability and amplitude drop precocity during phrenic threats. Clarity and legibility are significantly better with hepatic recording (sharper signals, less far-field QRS). The two main limitations were pacing instability and delay between 30% CMAP decrease and cryoapplication discontinuation.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2022 Tovmassian, Maille, Koutbi, Hourdain, Martinez, Zabern, Deharo and Franceschi.)
Details
- Language :
- English
- ISSN :
- 2297-055X
- Volume :
- 9
- Database :
- MEDLINE
- Journal :
- Frontiers in cardiovascular medicine
- Publication Type :
- Academic Journal
- Accession number :
- 35211527
- Full Text :
- https://doi.org/10.3389/fcvm.2022.814026