Back to Search Start Over

Associations With Extubation Failure and Predictive Value of Risk Analytics Algorithms With Extubation Readiness Tests Following Congenital Cardiac Surgery.

Authors :
Hames DL
Sleeper LA
Bullock KJ
Feins EN
Mills KI
Laussen PC
Salvin JW
Source :
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies [Pediatr Crit Care Med] 2022 Apr 01; Vol. 23 (4), pp. e208-e218. Date of Electronic Publication: 2022 Feb 21.
Publication Year :
2022

Abstract

Objectives: Extubation failure is associated with morbidity and mortality in children following cardiac surgery. Current extubation readiness tests (ERT) do not consider the nonrespiratory support provided by mechanical ventilation (MV) for children with congenital heart disease. We aimed to identify factors associated with extubation failure in children following cardiac surgery and assess the performance of two risk analytics algorithms for patients undergoing an ERT.<br />Design: Retrospective cohort study.<br />Setting: CICU at a tertiary-care children's hospital.<br />Patients: Children receiving MV greater than 48 hours following cardiac surgery between January 1, 2017, and December 31, 2019.<br />Interventions: None.<br />Measurements and Main Results: Six hundred fifty encounters were analyzed with 49 occurrences (8%) of reintubation. Extubation failure occurred most frequently within 6 hours of extubation. On multivariable analysis, younger age (per each 3-mo decrease: odds ratio [OR], 1.06; 95% CI, 1.001-1.12), male sex (OR, 2.02; 95% CI, 1.03-3.97), Society of Thoracic Surgery-European Association for Cardiothoracic Surgery category 5 procedure (p equals to 0.005), and preoperative respiratory support (OR, 2.08; 95% CI, 1.09-3.95) were independently associated with unplanned reintubation. Our institutional ERT had low sensitivity to identify patients at risk for reintubation (23.8%; 95% CI, 9.7-47.6%). The addition of the inadequate delivery of oxygen (IDO2) index to the ERT increased the sensitivity by 19.0% (95% CI, -2.5 to 40.7%; p = 0.05), but the sensitivity remained low and the accuracy of the test dropped by 8.9% (95% CI, 4.7-13.1%; p < 0.01).<br />Conclusions: Preoperative respiratory support, younger age, and more complex operations are associated with postoperative extubation failure. IDO2 and IVCO2 provide unique cardiorespiratory monitoring parameters during ERTs but require further investigation before being used in clinical evaluation for extubation failure.<br /> (Copyright © 2022 by the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.)

Details

Language :
English
ISSN :
1529-7535
Volume :
23
Issue :
4
Database :
MEDLINE
Journal :
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
Publication Type :
Academic Journal
Accession number :
35184097
Full Text :
https://doi.org/10.1097/PCC.0000000000002912