Back to Search
Start Over
Postoperative bleeding and leaks in sleeve gastrectomy are independent of both staple height and staple line oversewing.
- Source :
-
Surgical endoscopy [Surg Endosc] 2022 Sep; Vol. 36 (9), pp. 6924-6930. Date of Electronic Publication: 2022 Feb 04. - Publication Year :
- 2022
-
Abstract
- Background: Over 100,000 sleeve gastrectomy procedures are performed annually in the USA. Despite technological advances, postoperative bleeding and gastric staple line leak are complications of this procedure. We analyzed patient-specific and perioperative factors to determine their association with these complications.<br />Methods: We performed a retrospective cohort analysis of patients who underwent sleeve gastrectomy between 2005 and 2019 at our institution. Patient demographics, comorbidities, and procedure details including type of energy device, staple type, staple height, staple line oversewing, and staple line clipping were compared using multiple logistic regression for combined postoperative complications (blood transfusion, bleeding, and staple line leak). Postoperative bleeding was defined by requiring blood transfusion and/or re-operation to control bleeding. Staple line leak was confirmed radiographically.<br />Results: There were 1213 patients who underwent sleeve gastrectomy. Fifty-two high-risk patients were excluded due to cirrhosis, end-stage renal disease, and anticoagulation use for left ventricular assist device. Of the remaining 1161 patients, twenty-five (2.2%) received postoperative blood transfusion, nine (0.8%) had postoperative bleeding, two (0.2%) had staple line leak, and twenty-eight patients (2.4%) had combined postoperative complications. The median age was significantly higher for patients with combined postoperative complications (43 vs 49; p = 0.02). There was no difference in postoperative blood transfusion, bleeding, staple line leak, or combined postoperative complication with different energy devices (p = 0.92), staple types (p = 0.21), staple heights (p = 0.50), or staple line suturing/clipping (p = 0.95). In addition, there was no difference in bleeding when comparing staple line sewing techniques (p = 0.44). Predictably, patients with combined postoperative complications had increased length of stay (3 days vs 1 day; p < 0.001).<br />Conclusion: Sleeve gastrectomy procedure has tremendous variability in technique and devices used. We observed no difference in the combined postoperative complications of bleeding or staple line leak with respect to different energy devices, staple height, or oversewing of the gastric staple line. Patient selection is crucial, as patient age and coagulopathic comorbidities were found to lead to higher combined postoperative complications.<br /> (© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
- Subjects :
- Anastomotic Leak etiology
Gastrectomy adverse effects
Gastrectomy methods
Humans
Postoperative Complications epidemiology
Postoperative Complications etiology
Postoperative Complications surgery
Postoperative Hemorrhage epidemiology
Postoperative Hemorrhage etiology
Retrospective Studies
Surgical Stapling methods
Laparoscopy methods
Obesity, Morbid complications
Obesity, Morbid surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1432-2218
- Volume :
- 36
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Surgical endoscopy
- Publication Type :
- Academic Journal
- Accession number :
- 35122150
- Full Text :
- https://doi.org/10.1007/s00464-022-09031-1