Back to Search Start Over

Optimizing the Angiography Protocol to Reduce Radiation Dose in Uterine Artery Embolization: The Impact of Digital Subtraction Angiographies on Radiation Exposure.

Authors :
Cina A
Steri L
Barbieri P
Contegiacomo A
Amodeo EM
Di Stasi C
Morasca A
Romualdi D
Ciccarone F
Manfredi R
Source :
Cardiovascular and interventional radiology [Cardiovasc Intervent Radiol] 2022 Feb; Vol. 45 (2), pp. 249-254. Date of Electronic Publication: 2022 Jan 14.
Publication Year :
2022

Abstract

Purpose: The aim was to compare a protocol of uterine artery embolization (UAE) consisting in three digital subtraction angiographies (DSAs)-Group A, with a protocol based on a single DSA-Group B.<br />Materials and Methods: This is a single-center prospective randomized study enrolling 20 women (mean age 41 years, range 22-55 years) with uterine fibroids treated with UAE, from January 2015 to February 2016. All UAEs were performed by two interventional radiologists using the same angiography machine. Protocol of Group A consisted in three DSA runs (non-selective pelvic view and selective uterine views before and after embolization). Protocol of Group B consisted in 1 DSA run: selective UA angiography before embolization. (Fluoroscopic roadmap was used for UA catheterization; fluoroscopy storage was used as control after embolization.) Each patient was randomized to receive Protocol A in one pelvic side and Protocol B on the other.<br />Results: All patients received bilateral UAE. Mean fluoroscopy time for UA catheterization was 11.3 ± 3.7 s. (Protocol A) and 9.93 ± 2.99 s. (Protocol B) (p = 0.19). Fluoroscopy dose for catheterization and embolization was not different between both protocols (p = 0.14). Identification of the UA origin score was similar in both protocols (median error = 0, p = 0.79). Mean dose area product (DAP) was 40859 mGy/cm <superscript>2</superscript> (Protocol A) and 28839 mGy/cm <superscript>2</superscript> (Protocol B) (p = 0.003). Mean effective dose (ED) decreased from Protocol A (14.6 mSv) to Protocol B (9.2 mSv; - 37%). Mean absorbed dose (AD) to ovaries and uterus, respectively, decreased of 53% and 55% from Protocol A to Protocol B.<br />Conclusion: Reducing the number of DSA runs from 3 to 1 during UAE allows at least a 30% reduction on radiation exposure, without compromising technical outcomes.<br /> (© 2021. Springer Science+Business Media, LLC, part of Springer Nature and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE).)

Details

Language :
English
ISSN :
1432-086X
Volume :
45
Issue :
2
Database :
MEDLINE
Journal :
Cardiovascular and interventional radiology
Publication Type :
Academic Journal
Accession number :
35028722
Full Text :
https://doi.org/10.1007/s00270-021-03032-8