Back to Search Start Over

Foley catheter and controlled release dinoprostone versus foley catheter labor induction in nulliparas: a randomized trial.

Authors :
Vallikkannu N
Laboh N
Tan PC
Hong JGS
Hamdan M
Lim BK
Source :
Archives of gynecology and obstetrics [Arch Gynecol Obstet] 2022 Oct; Vol. 306 (4), pp. 1027-1036. Date of Electronic Publication: 2022 Jan 09.
Publication Year :
2022

Abstract

Purpose: To evaluate Foley catheter and controlled release dinoprostone insert compared to foley catheter alone on induction to delivery interval and maternal satisfaction.<br />Methods: A randomized trial was conducted in a university hospital in Malaysia from December 2018 to May 2019. Term nulliparas with unfavorable cervix (Bishop score ≤ 5) scheduled for labor induction were randomized to Foley catheter and controlled release dinoprostone insert simultaneously or Foley catheter alone. Primary outcomes were induction to delivery interval (hours) and maternal satisfaction on birth experience (assessed by 11-point Visual Numerical Rating Scale VNRS 0-10, higher score more satisfied).<br />Results: Induction to vaginal delivery intervals was mean ± standard deviation 22.5 ± 10.4 vs. 35.1 ± 14.9 h, P =  < 0.001 but maternal satisfaction on birth experience was not significantly different median[interquartile range] VNRS 8[7-9] vs. 8[7-9], P = 0.12 for Foley catheter-controlled-release dinoprostone and Foley catheter alone arms, respectively. Cesarean delivery rates were 35/102(34.3%) vs. 50/101(49.5%), P = 0.02 RR 0.7 95% CI 0.5-0.9 NNTb 6.3 95% CI 3.5-39.4, pain score at 6 h after catheter insertion 5[2-8] vs. 1[1-3], P < 0.001, Bishop score at trial devices removal 9[9-10] vs. 8[7-9], P = 0.001, requirement for oxytocin induction or augmentation 39/102(38.2%) vs. 76/101(75.2%) NNTb 3 95% CI 2.0-4.1, P < 0.001 and amniotomy rates 73/99(73.7%) vs. 81/95(85.3%), P = 0.052 RR 0.9 85% CI 0.8-1.0 in Foley catheter-controlled-release dinoprostone and Foley catheter alone arms respectively.<br />Conclusion: In nulliparas with unripe cervixes at term, combined Foley catheter and controlled release dinoprostone vaginal insert compared to Foley catheter alone reduces the induction to vaginal delivery interval and cesarean delivery rate but satisfaction was not significantly increased.<br />Clinical Trial Registration: ISRCTN2282883, 03/12/2018, "prospectively registered" ( https://doi.org/10.1186/ISRCTN12282883 ).<br /> (© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)

Details

Language :
English
ISSN :
1432-0711
Volume :
306
Issue :
4
Database :
MEDLINE
Journal :
Archives of gynecology and obstetrics
Publication Type :
Academic Journal
Accession number :
34999923
Full Text :
https://doi.org/10.1007/s00404-021-06383-2