Back to Search Start Over

Procedural Safety and Efficacy for Pulmonary Vein Isolation with the Novel Polarx™ Cryoablation System: A Propensity Score Matched Comparison with the Arctic Front™ Cryoballoon in the Setting of Paroxysmal Atrial Fibrillation.

Authors :
Mojica J
Lipartiti F
Al Housari M
Bala G
Kazawa S
Miraglia V
Monaco C
Overeinder I
Strazdas A
Ramak R
Paparella G
Sieira J
Capulzini L
Sorgente A
Stroker E
Brugada P
De Asmundis C
Chierchia GB
Source :
Journal of atrial fibrillation [J Atr Fibrillation] 2021 Jun 30; Vol. 14 (1), pp. 20200455. Date of Electronic Publication: 2021 Jun 30 (Print Publication: 2021).
Publication Year :
2021

Abstract

Background: The novel Polarx™ cryoablation system is currently being studied for atrial fibrillation (AF) ablation. To the best of our knowledge, no study comparing the novel cryoablation system with the standard Arctic Front™ cryoballoon is available in today's literature. This study aims to compare Polarx™ and Arctic Front™ cryoballoon in terms of safety and efficacy.<br />Methods: From a total cohort of 202 patients who underwent pulmonary vein (PV) isolation for paroxysmal AF through cryoablation, a population of 30 patients who used Polarx™ were compared with 30 propensity-score matched patients who used Arctic Front™.<br />Results: Pulmonary vein occlusion and electrical isolation were achieved in all (100%) veins with a mean number of 1.09 ± 0.3 occlusion per vein using Polarx™ and 1.19 ± 0.5 occlusion per vein using Arctic Front™ (p = 0.6). Shorter procedure and fluoroscopy time were observed with Polarx™ group (60.5 ± 14.23 vs 73.43 ± 13.26 mins, p = 0.001; 12.83 ± 6.03 vs 17.23 ± 7.17 mins, p = 0.01, respectively). Lower cumulative freeze duration per vein was also observed with Polarx™ (203.38 ± 72.03 vs 224.9 ± 79.35 mins, p = 0.02). There was no significant difference in isolation time between the two groups (34.47 ± 21.23 vs 34.18 ± 26.79 secs, p = 0.9).<br />Conclusions: The novel Polarx™ cryoablation system showed similar efficacy in vein occlusion and isolation and safety profile when compared to Arctic Front™ cryoablation system. Procedure time, fluoroscopy time, and cumulative freeze duration were significantly lower with Polarx™ cryoablation system.

Details

Language :
English
ISSN :
1941-6911
Volume :
14
Issue :
1
Database :
MEDLINE
Journal :
Journal of atrial fibrillation
Publication Type :
Academic Journal
Accession number :
34950358
Full Text :
https://doi.org/10.4022/jafib.20200455