Back to Search
Start Over
Contrast-enhanced Mammography: A Systematic Review and Meta-Analysis of Diagnostic Performance.
- Source :
-
Radiology [Radiology] 2022 Mar; Vol. 302 (3), pp. 568-581. Date of Electronic Publication: 2021 Dec 14. - Publication Year :
- 2022
-
Abstract
- Background Contrast-enhanced mammography (CEM) is a promising technique for breast cancer detection, but conflicting results have been reported in previous meta-analyses. Purpose To perform a systematic review and meta-analysis of CEM diagnostic performance considering different interpretation methods and clinical settings. Materials and Methods The MEDLINE, EMBASE, Web of Science, and Cochrane Library databases were systematically searched up to July 15, 2021. Prospective and retrospective studies evaluating CEM diagnostic performance with histopathology and/or follow-up as the reference standard were included. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Summary diagnostic odds ratio and area under the receiver operating characteristic curve were estimated with the hierarchical summary receiver operating characteristic (HSROC) model. Summary estimates of sensitivity and specificity were obtained with the hierarchical bivariate model, pooling studies with the same image interpretation approach or focused on the same findings. Heterogeneity was investigated through meta-regression and subgroup analysis. Results Sixty studies (67 study parts, 11 049 CEM examinations in 10 605 patients) were included. The overall area under the HSROC curve was 0.94 (95% CI: 0.91, 0.96). Pooled diagnostic odds ratio was 55.7 (95% CI: 42.7, 72.7) with high heterogeneity (τ <superscript>2</superscript> = 0.3). At meta-regression, CEM interpretation with both low-energy and recombined images had higher sensitivity (95% vs 94%, P < .001) and specificity (81% vs 71%, P = .03) compared with recombined images alone. At subgroup analysis, CEM showed a 95% pooled sensitivity (95% CI: 92, 97) and a 78% pooled specificity (95% CI: 66, 87) from nine studies in patients with dense breasts, while in 10 studies on mammography-detected suspicious findings, CEM had a 92% pooled sensitivity (95% CI: 89, 94) and an 84% pooled specificity (95% CI: 73, 91). Conclusion Contrast-enhanced mammography demonstrated high performance in breast cancer detection, especially with joint interpretation of low-energy and recombined images. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Bahl in this issue.
- Subjects :
- Female
Humans
Breast Neoplasms diagnostic imaging
Contrast Media
Mammography methods
Subjects
Details
- Language :
- English
- ISSN :
- 1527-1315
- Volume :
- 302
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 34904875
- Full Text :
- https://doi.org/10.1148/radiol.211412