Case Report: Spinal Stabilization Surgery Using a Novel Custom-Made Titanium Fixation System for the Spinal Instability Caused by Vertebral Malformation in a Dog.
- Source :
-
Frontiers in veterinary science [Front Vet Sci] 2021 Nov 10; Vol. 8, pp. 755572. Date of Electronic Publication: 2021 Nov 10 (Print Publication: 2021). - Publication Year :
- 2021
-
Abstract
- A 2-year-old Maltese was presented with wobbly gait of the pelvic limbs. Based on imaging examinations, a diagnosis of congenital malformation at T5-T8 and severe kyphosis causing spinal cord compression at T6-T7 was made. Dorsal laminectomy and stabilization of T6 and T7 vertebrae were performed. As the size of the vertebrae was small and they were severely deformed, novel custom-made titanium implants were used for spinal stabilization. Clinical signs were resolved 2 weeks after surgery. Although radiographic examination 373 days after surgery showed slight loosening of implants, post-operative course remained uneventful. This report describes the use of novel custom-made titanium implants for spinal fixation surgery in a dog.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2021 Kimura, Nakata, Nakano, Nozue, Konno, Sugawara, Maeda and Kamishina.)