Back to Search
Start Over
Accuracy of commercial 3D printers for the fabrication of surgical guides in dental implantology.
- Source :
-
Journal of dentistry [J Dent] 2022 Feb; Vol. 117, pp. 103909. Date of Electronic Publication: 2021 Nov 28. - Publication Year :
- 2022
-
Abstract
- Objectives: To evaluate the accuracy of two different surgical guides (small extent = single implant and large extent = full arch) fabricated by five additive manufacturing technologies (SLA=Stereolithography, DLP= Digital Light Processing, FDM=Fused Deposition Modeling, SLS=Selective Laser Sintering, Inkjet).<br />Methods: Overall, 72 guides (6 per type) were obtained with the different machines (SLA=Form2; DLP=Rapid Shape D40 and Cara Print 4.0; FDM=Raise 3D Pro2; SLS=Prodways P1000; Polyjet®=Stratasys J750). The guides were surface-scanned with an optical dental scanner, and the resulting files were compared with the initial design files using a surface matching software. Root Mean Square (RMS) and standard deviation were calculated, representing respectively trueness and precision. Kruskall-Wallis non-parametric test was used to compare trueness and precision between small-extent and large-extent guides and 3D printer by pairs. The threshold for significance was α=0.05, except for the comparison of printers by pairs where a Bonferroni-corrected level of 0.0033 was used.<br />Results: Significant differences were observed for trueness and precision between small-extent and large-extent guides, regardless the printer except for DLP (trueness and precision) and SLS (precision). SLA, DLP and Polyjet® technologies showed similar results in terms of trueness and precision for both small-extend and large-extend guides (P>0.05).<br />Conclusions: The size affected the accuracy of CAD-CAM surgical guides. The different additive manufacturing technologies had a limited impact on the accuracy.<br />Clinical Significance: This study is of clinical interest as it shows that the 3D printing technology (SLA/DLP) has a limited impact on 3D printed surgical guides accuracy. However, the size of the guide can have a significant impact, as small-extent guides were more accurate than large-extent guides.<br /> (Copyright © 2021 Elsevier Ltd. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1879-176X
- Volume :
- 117
- Database :
- MEDLINE
- Journal :
- Journal of dentistry
- Publication Type :
- Academic Journal
- Accession number :
- 34852291
- Full Text :
- https://doi.org/10.1016/j.jdent.2021.103909