Back to Search Start Over

Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres.

Authors :
Roosen J
Arntz MJ
Janssen MJR
de Jong SF
Fütterer JJ
Overduin CG
Nijsen JFW
Source :
Cancers [Cancers (Basel)] 2021 Oct 30; Vol. 13 (21). Date of Electronic Publication: 2021 Oct 30.
Publication Year :
2021

Abstract

Selective internal radiation therapy (SIRT) is a treatment modality for liver tumours during which radioactive microspheres are injected into the hepatic arterial tree. Holmium-166 ( <superscript>166</superscript> Ho) microspheres used for SIRT can be visualized and quantified with MRI, potentially allowing for MRI guidance during SIRT. The purpose of this study was to investigate the MRI compatibility of two angiography catheters and a microcatheter typically used for SIRT, and to explore the detectability of <superscript>166</superscript> Ho microspheres in a flow phantom using near real-time MRI. MR safety tests were performed at a 3 T MRI system according to American Society for Testing of Materials standard test methods. To assess the near real-time detectability of <superscript>166</superscript> Ho microspheres, a flow phantom was placed in the MRI bore and perfused using a peristaltic pump, simulating the flow in the hepatic artery. Dynamic MR imaging was performed using a 2D FLASH sequence during injection of different concentrations of <superscript>166</superscript> Ho microspheres. In the safety assessment, no significant heating (ΔT <subscript>max</subscript> 0.7 °C) was found in any catheter, and no magnetic interaction was found in two out of three of the used catheters. Near real-time MRI visualization of <superscript>166</superscript> Ho microsphere administration was feasible and depended on holmium concentration and vascular flow speed. Finally, we demonstrate preliminary imaging examples on the in vivo catheter visibility and near real-time imaging during <superscript>166</superscript> Ho microsphere administration in an initial patient case treated with SIRT in a clinical 3 T MRI. These results support additional research to establish the feasibility and safety of this procedure in vivo and enable the further development of a personalized MRI-guided approach to SIRT.

Details

Language :
English
ISSN :
2072-6694
Volume :
13
Issue :
21
Database :
MEDLINE
Journal :
Cancers
Publication Type :
Academic Journal
Accession number :
34771626
Full Text :
https://doi.org/10.3390/cancers13215462