Back to Search
Start Over
Efficacy of an Intranasal Tear Neurostimulator in Sjögren Syndrome Patients.
- Source :
-
Clinical ophthalmology (Auckland, N.Z.) [Clin Ophthalmol] 2021 Oct 27; Vol. 15, pp. 4291-4296. Date of Electronic Publication: 2021 Oct 27 (Print Publication: 2021). - Publication Year :
- 2021
-
Abstract
- Purpose: To assess the efficacy and safety of an intranasal tear neurostimulator (ITN) device in Sjögren syndrome (SS) patients.<br />Methods: This was a two-visit prospective, randomized, controlled, same-day crossover study in participants with SS. Inclusion criteria were assessed at a baseline screening visit and included an Ocular Surface Disease Index (OSDI) score ≥13, and a Schirmer with anesthesia ≤10 mm/5 min (in at least one eye), with a cotton swab stimulation induced increase of ≥4 mm in the same eye. Participants returned for the application visit, where they received intranasal and extranasal applications of the ITN in random sequence, separated by at least 60 min. Schirmer scores were measured in both eyes after each application and compared to baseline values. Generalized linear models were performed to compare the change in Schirmer scores from baseline, and generalized estimating equations were used to account for correlations from repeated measurements in the same eye and measurements from two eyes of the same patient.<br />Results: Fifty-five participants were screened and 35 were enrolled (all female), ranging in age from 31 to 72 years (mean, 57 years). The baseline OSDI score ranged from 14 to 91 (mean, 50.5), and the baseline Schirmer score had a mean (SD) of 6.4 (3.5) ranging from 0 to 20 (mm/5min). Improvement in Schirmer scores was significantly greater for intranasal device application (13.5 mm/5min, 95% CI: 10.4, 16.5) compared to extranasal device application (0.8mm/5min, 95% CI: -0.9, 2.4) (p<0.0001). The effects of the intranasal device application were significant regardless of the participant's baseline Schirmer score and systemic SS medication usage (p<0.05).<br />Conclusion: Intranasal application of the ITN device significantly increased tear production in a subset of SS patients compared to baseline and was more effective than extranasal application. While production of the ITN device was recently discontinued, our findings suggest that other therapies that neurostimulate the lacrimal function unit may be effective in a subset of SS patients.<br />Competing Interests: VYB reports grant support from Bausch & Lomb (NEI R01 EY026972); a consultant in 2019 for Verily and also reports patents issued EP 3210201 US 10360819 US 10783505. GSY and PH are supported by NIH grant EY001583 for the statistical work for this paper. MMG is a consultant for Lynthera and owns stocks from PRN. The authors report no other conflicts of interest in this work.<br /> (© 2021 Lilley et al.)
Details
- Language :
- English
- ISSN :
- 1177-5467
- Volume :
- 15
- Database :
- MEDLINE
- Journal :
- Clinical ophthalmology (Auckland, N.Z.)
- Publication Type :
- Academic Journal
- Accession number :
- 34737542
- Full Text :
- https://doi.org/10.2147/OPTH.S312108