Back to Search
Start Over
Removable partial dentures retained by hybrid CAD/CAM cobalt-chrome double crowns: 1-year results from a prospective clinical study: CAD/CAM cobalt-chrome double crowns: 1-year results.
- Source :
-
Journal of dentistry [J Dent] 2021 Dec; Vol. 115, pp. 103847. Date of Electronic Publication: 2021 Oct 20. - Publication Year :
- 2021
-
Abstract
- Objectives: Computer-aided design and manufacturing (CAD/CAM) has been successfully used to replace conventional steps in the fabrication of double crowns, creating hybrid-workflows that might facilitate the wider application of these restorations in the future. However, in-vivo data are still lacking.<br />Methods: A prospective clinical trial was designed in which 20 patients (median age = 69 years; n women = 10) with 73 abutment teeth who needed a double-crown-retained removable partial denture (RPD) were consecutively recruited. While most of the work steps were done conventionally, gypsum models were digitized with a laboratory scanner to allow CAD/CAM fabrication of primary crowns and secondary structures. DentalDesigner software (3Shape) was used in combination with milling unit PrograMillPM7 and Co-Cr- blanks (Ivoclar-vivadent). Connectors were milled from wax, transferred to Co-Cr using lost-wax technique and bonded to the secondary crowns. Clinical follow-ups were scheduled 6 and 12 months after prosthesis insertion. Outcome parameters were complication-free survival of RPDs and abutment teeth after one year.<br />Results: After 12 months, complication-free survival was 74% and 91% for the RPDs and abutment teeth, respectively. Complications comprised decementations (n = 5), abutment tooth fractures (n = 2), fracture of denture teeth (n = 1), and loss of abutment teeth (n = 1). These complications were easily manageable, resulting in 1-year survival of 100% for CAD/CAM RPDs.<br />Conclusions: First data on short-term complication rates of CAD/CAM double-crown-retained RPDs appear promising. To gather further evidence, prospective clinical trials over a longer follow-up time and with larger patient groups are required.<br />Clinical Significance: Hybrid CAD/CAM double-crown retained RPDs showed a successful clinical application after one year of follow-up. Further research is needed to evaluate their performance in comparison to conventional manufacturing methods.<br /> (Copyright © 2021. Published by Elsevier Ltd.)
Details
- Language :
- English
- ISSN :
- 1879-176X
- Volume :
- 115
- Database :
- MEDLINE
- Journal :
- Journal of dentistry
- Publication Type :
- Academic Journal
- Accession number :
- 34678336
- Full Text :
- https://doi.org/10.1016/j.jdent.2021.103847