Back to Search
Start Over
Clinical examination for hyperlinear palms to determine filaggrin genotype: A diagnostic test accuracy study.
Clinical examination for hyperlinear palms to determine filaggrin genotype: A diagnostic test accuracy study.
- Source :
-
Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology [Clin Exp Allergy] 2021 Nov; Vol. 51 (11), pp. 1421-1428. Date of Electronic Publication: 2021 Oct 18. - Publication Year :
- 2021
-
Abstract
- Background: Palmar hyperlinearity is a feature of ichthyosis vulgaris, the monogenic skin disorder caused by FLG loss-of-function mutations.<br />Objective: To investigate how well the presence or absence of hyperlinear palms (HLP) detect FLG genotype in children.<br />Methods: STARD criteria are used to report this diagnostic accuracy study. Phenotype and genotype data (four most prevalent FLG null mutations) were obtained from a total of 3656 children in three studies: the UK CLOTHES trial (children 1-5 years with moderate-severe atopic eczema); UK BEEP trial (2 year olds at high risk of developing atopic eczema); UK-Irish eczema case collection (0-16 year olds with atopic eczema). All participants included in analyses of HLP as the index test and FLG genotype as the reference were of white European ancestry.<br />Results: Thirty-two percent of participants (1159/3656) had FLG null mutation(s) and 37% (1347/3656) had HLP. In 13% (464/3656), HLP was recorded as 'unsure' or not recorded. The sensitivity and specificity of HLP for detecting FLG mutations in each of the studies was: 67% (95% CI 55-78%) and 75% (67-82%) in CLOTHES; 46% (36-55%) and 89% (86-91%) in BEEP; 72% (68-75%) and 60% (57-62%) in the UK-Irish case collection. Positive and negative likelihood ratios were: 2.73 (1.95-3.81) and 0.44 (0.31-0.62) in CLOTHES; 4.02 (2.99-5.40) and 0.61 (0.52-0.73) in BEEP; 1.79 (1.66-1.93) and 0.47 (0.42-0.53) in the UK-Irish collection.<br />Discussion: Trained observers were able to define palmar hyperlinearity in the majority (3191/3656, 87%) of cases. The presence of HLP is not a reliable sign to detect FLG mutations, but the absence of HLP excludes FLG null genotype with a reasonable degree of certainty.<br /> (© 2021 The Authors. Clinical & Experimental Allergy published by John Wiley & Sons Ltd.)
Details
- Language :
- English
- ISSN :
- 1365-2222
- Volume :
- 51
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology
- Publication Type :
- Academic Journal
- Accession number :
- 34608691
- Full Text :
- https://doi.org/10.1111/cea.14025