Polyethylene liner cementation into a well-fixed metal acetabular shell for the management of periacetabular osteolysis: a systematic review.
- Source :
-
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie [Eur J Orthop Surg Traumatol] 2022 Dec; Vol. 32 (8), pp. 1459-1468. Date of Electronic Publication: 2021 Oct 04. - Publication Year :
- 2022
-
Abstract
- Purpose: Although various papers have reported on the clinical performance of cup retention with cementation of a new liner and bone grafting in the management of well-fixed cups with polyethylene wear and periacetabular osteolysis after total hip arthroplasty (THA), no systematic review of this topic has been published to date.<br />Methods: Medline, EMBASE and Cochrane Library were searched for articles published from January 1999 to January 2019 using "osteolysis" AND "well-fixed", "osteolysis" AND "retro-acetabular", "bone graft" AND ("retention" OR "retained" OR "stable") AND "cup", and "cemented liner" AND "well-fixed".<br />Results: Nine articles were selected for review (186 cases, 76.1 months mean follow-up). The overall revision rate was 11.3% (21 hips) most commonly due to aseptic loosening (9/186 hips), dislocation (8/186 hips), and liner wear progression (2/186 cases). The reported square size of osteolytic lesions ranged from a mean of 465.84 mm <superscript>2</superscript> to a max of 4,770 mm <superscript>2</superscript> . Almost all reported lesions treated with bone grafts resolved or did not progress 97% (72/74). All studies indicated improved pain and functional scores at follow-up.<br />Conclusion: Cementation of a new liner with periacetabular bone grafting provides an alternative option to isolated liner exchange and cup revision for the management of periacetabular osteolysis in well-fixed cups with a disrupted locking mechanism or unavailable exchange liner. Further higher quality studies are required in order to examine if the use of highly cross-linked polyethylene, highly porous-coated cups, hydroxyapatite-coated cups, and small-diameter cups influence the clinical outcome of liner cementation in well-fixed cups with periacetabular osteolysis.<br /> (© 2021. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.)
Details
- Language :
- English
- ISSN :
- 1432-1068
- Volume :
- 32
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- European journal of orthopaedic surgery & traumatology : orthopedie traumatologie
- Publication Type :
- Academic Journal
- Accession number :
- 34605989
- Full Text :
- https://doi.org/10.1007/s00590-021-03130-w