Back to Search Start Over

A balloon-borne imaging Fourier transform spectrometer for atmospheric trace gas profiling.

Authors :
Runge E
Langille J
Schentag C
Bourassa A
Letros D
Loewen P
Lloyd N
Degenstein D
Grandmont F
Source :
The Review of scientific instruments [Rev Sci Instrum] 2021 Sep 01; Vol. 92 (9), pp. 094502.
Publication Year :
2021

Abstract

The upper troposphere and lower stratosphere (UTLS) region is a highly variable region of the atmosphere and critical for understanding climate. Yet, it remains undersampled in the observational satellite record. Due to recent advances in interferometer and infrared detection technologies, imaging Fourier transform spectrometer (FTS) technology has been identified as a feasible remote sensing approach to obtain the required precision and spatial resolution of atmospheric trace gas composition in the UTLS. Building on the success of instruments such as the Michelson Interferometer for Passive Atmospheric Sounding and gimbaled limb observer for radiance imaging of the atmosphere, the limb imaging Fourier transform spectrometer experiment (LIFE) instrument, of which this paper details the design and performance, is a balloon-borne infrared imaging FTS developed as an early prototype of a low earth orbit satellite instrument. LIFE is constructed primarily with commercially available off-the-shelf components, with a design emphasis on greatly reducing the complexity of the instrument, particularly the cooling requirements, with a minimal reduction in information gain on the target atmospheric greenhouse gases of water vapor, methane, ozone, and nitrous oxide. The developed instrument was characterized through a series of thermal and vacuum tests and validated through a successful demonstration balloon flight during the 2019 Strato-Science campaign in Canada. In the calibration of the data from the balloon flight, an issue was identified regarding a lack of knowledge in the emissivity of the on-board blackbody calibration sources. These systematic effects were minimized through the application of an emissivity ratio determined from the characterization tests where a wider range of known blackbody temperatures were available. Despite this identified calibration issue, the results demonstrate that the instrument is capable of meeting primary performance requirements for trace gas retrievals of the target atmospheric species.

Details

Language :
English
ISSN :
1089-7623
Volume :
92
Issue :
9
Database :
MEDLINE
Journal :
The Review of scientific instruments
Publication Type :
Academic Journal
Accession number :
34598537
Full Text :
https://doi.org/10.1063/5.0060125