Back to Search Start Over

Mass spectrometry determination of seized oil-based anabolic-androgenic steroids products.

Authors :
Coimbra MA
Barbosa FS
Scheid C
Macedo SMD
Yonamine M
Merib JO
Oliveira TF
Eller S
Source :
Forensic science international [Forensic Sci Int] 2021 Nov; Vol. 328, pp. 111012. Date of Electronic Publication: 2021 Sep 22.
Publication Year :
2021

Abstract

Introduction: The presence of anabolic-androgenic steroids (AAS) in illegal commercial products has been pointed as a global threat for public health. Due the correlation with adverse toxicological effects, there is a growing interest in the implementation of straightforward methods for the determination of AAS in seized products. This work exploited the development of a mass spectrometry approach to characterize the illegal oil formulations containing AAS.<br />Methods: The optimization of sample preparation was performed through a simplex-centroid design and the best condition was described as follow: an aliquot of 5 μL of sample were added with 995 μL of acetonitrile and water (75:25, v/v). The solution was vortexed and centrifuged. After that, 10 μL of supernatant were added with 35 μL of acetonitrile and water and internal standard (testosterone-d <subscript>3</subscript> , 1.25 ng). An aliquot of 5 μL was injected into the analytical system.<br />Results: The method developed was validated and successfully applied in 115 seized samples. Testosterone and its esters had the highest incidence, found in more than 50% of the samples. Besides that, drugs such as boldenone, methandienone, and trenbolone have also been found, where the low quality of the samples was evidenced by the wide variation in the concentration of the drugs, always quantified in sub-doses. Finally, at least one AAS was detected in each sample analyzed. The statistical results were grouped by principal components analysis, to better understand the profile of the seized samples.<br />Conclusion: This work successfully established a fast and simple method for determination of AAS and can be applied to verify the profile of seized samples.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2021 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1872-6283
Volume :
328
Database :
MEDLINE
Journal :
Forensic science international
Publication Type :
Academic Journal
Accession number :
34587560
Full Text :
https://doi.org/10.1016/j.forsciint.2021.111012