Back to Search Start Over

Outcomes of 10,312 patients treated with everolimus-eluting bioresorbable scaffolds during daily clinical practice - results from the European Absorb Consortium.

Authors :
Wiebe J
Hofmann FJ
West N
Baumbach A
Carrie D
Bermudez EP
Cayla G
Hernandez FH
de la Torre Hernandez JM
Koning R
Loi B
Moscarella E
Tarantini G
Zaman A
Lober C
Riemer T
Achenbach S
Hamm CW
Nef HM
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2022 Feb; Vol. 99 (3), pp. 533-540. Date of Electronic Publication: 2021 Aug 31.
Publication Year :
2022

Abstract

Objectives: To asses mid-term clinical outcomes of bioresorbable vascular scaffolds (BVS) for the treatment of coronary artery disease in a large-scale all-comers population.<br />Background: Several clinical settings are underrepresented in randomized studies investigating BVS against drug-eluting stents. Whether their results can be translated into the heterogeny patient population seen during daily routine requires further investigation.<br />Methods: The European ABSORB Consortium comprises the following European registries: GABI-R, ABSORB UK Registry, ABSORB France, BVS RAI Registry, and REPARA BVS Registry, which all prospectively collected patient-level data regarding outcomes following unrestricted BVS implantation. The primary endpoint of target lesion failure (TLF) includes cardiac death, target-vessel myocardial infarction (TVMI) and target-lesion revascularisation (TLR) at 12 months. The incidence of scaffold thrombosis (ST) according to ARC criteria was also assessed. Multivariable analysis was used to adjust for differences in patient and lesion characteristics.<br />Results: A total of 10,312 patients (mean age 58.4 ± 11.4 y) underwent BVS implantation during routine practice. The 12-month follow-up was complete in 95.5% of patients. At 12 months, the primary endpoint of TLF occurred in 3.6%; its components cardiac death, TVMI and TLR were documented in 1.2%, 1.8%, and 2.6%, respectively. The definite/probable ST rate was 1.7%. Absence of predilatation, discontinuation of DAPT and scaffold diameter below 3 mm were independent predictors of ST.<br />Conclusions: The EAC demonstrates reasonable real-world clinical outcome data after BVS implantation. However, the rate of scaffold thrombosis remains high.<br /> (© 2021 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC.)

Details

Language :
English
ISSN :
1522-726X
Volume :
99
Issue :
3
Database :
MEDLINE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Type :
Academic Journal
Accession number :
34463427
Full Text :
https://doi.org/10.1002/ccd.29932