Back to Search Start Over

Microvascular blood flow changes of the abductor pollicis brevis muscle during sustained static exercise.

Authors :
Giovannella M
Urtane E
Zanoletti M
Karadeniz U
Rubins U
Weigel UM
Marcinkevics Z
Durduran T
Source :
Biomedical optics express [Biomed Opt Express] 2021 Jun 18; Vol. 12 (7), pp. 4235-4248. Date of Electronic Publication: 2021 Jun 18 (Print Publication: 2021).
Publication Year :
2021

Abstract

A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant changes in the systemic physiology that influence the muscle hemodynamics, we have observed that the high MVC group showed a 56% and 36% decrease in the blood flow during exercise, with respect to baseline, in the long and short source-detector (SD) separations (p=0.031 for both). No statistical differences were shown for the low MVC group (p=1 for short and p=0.15 for long SD). These results suggest that the mechanical occlusion, due to increased intramuscular pressure, exceeded the vasodilation elicited by the higher metabolic demand. Also, blood flow changes during thumb contraction negatively correlated (R=-0.7, p<0.01) with the absolute force applied by each subject. Furthermore, after the exercise, muscular blood flow increased significantly immediately after thumb contractions in both high and low MVC groups, with respect to the recorded values during the exercise (p=0.031). An increase of 251% (200%) was found for the long (short) SD in the low MVC group. The high MVC groups showed a significant 90% increase in blood flow only after 80 s from the start of the protocol. For both low and high MVC groups, blood flow recovered to baseline values within 160 s from starting the exercise. In conclusion, DCS allows the study of the response of a small muscle to static exercise and can be potentially used in multiple clinical conditions scenarios for assessing microvascular health.<br />Competing Interests: Turgut Durduran is an inventor on relevant patents (Patent US8082015B2, "Optical measurement of tissue blood flow, hemodynamics and oxygenation”). ICFO has equity ownership in the spin-off company HemoPhotonics S.L. Potential financial conflicts of interest and objectivity of research have been monitored by ICFO’s Knowledge & Technology Transfer Department. No financial conflicts of interest were identified. Udo Weigel is the CEO, has equity ownership in HemoPhotonics S.L. and is an employee in the company.<br /> (© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.)

Details

Language :
English
ISSN :
2156-7085
Volume :
12
Issue :
7
Database :
MEDLINE
Journal :
Biomedical optics express
Publication Type :
Academic Journal
Accession number :
34457411
Full Text :
https://doi.org/10.1364/BOE.427885