Back to Search Start Over

1-Year Results From a Prospective Experience on CAS Using the CGuard Stent System: The IRONGUARD 2 Study.

Authors :
Sirignano P
Stabile E
Mansour W
Capoccia L
Faccenna F
Intrieri F
Ferri M
SaccĂ  S
Sponza M
Mortola P
Ronchey S
Praquin B
Grillo P
Chiappa R
Losa S
Setacci F
Pirrelli S
Taurino M
Ruffino MA
Udini M
Palombo D
Ippoliti A
Montelione N
Setacci C
de Donato G
Ruggeri M
Speziale F
Source :
JACC. Cardiovascular interventions [JACC Cardiovasc Interv] 2021 Sep 13; Vol. 14 (17), pp. 1917-1923. Date of Electronic Publication: 2021 Aug 11.
Publication Year :
2021

Abstract

Objectives: The aim of this study was to evaluate the 1-year safety and efficacy of a dual-layered stent (DLS) for carotid artery stenting (CAS) in a multicenter registry.<br />Background: DLS have been proved to be safe and efficient during short-term follow-up. Recent data have raised the concern that the benefit of CAS performed with using a DLS may be hampered by a higher restenosis rate at 1 year.<br />Methods: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system at 20 centers. The primary endpoint was the occurrence of death and stroke at 1 year. Secondary endpoints were 1-year rates of transient ischemic attack, acute myocardial infarction, internal carotid artery (ICA) restenosis, in-stent thrombosis, and external carotid artery occlusion.<br />Results: At 1 year, follow-up was available in 726 patients (99.04%). Beyond 30 days postprocedure, 1 minor stroke (0.13%), four transient ischemic attacks (0.55%), 2 fatal acute myocardial infarctions (0.27%), and 6 noncardiac deaths (1.10%) occurred. On duplex ultrasound examination, ICA restenosis was found in 6 patients (0.82%): 2 total occlusions and 4 in-stent restenoses. No predictors of target ICA restenosis and/or occlusion could be detected, and dual-antiplatelet therapy duration (90 days vs 30 days) was not found to be related to major adverse cardiovascular event or restenosis occurrence.<br />Conclusions: This real-world registry suggests that DLS use in clinical practice is safe and associated with minimal occurrence of adverse neurologic events up to 12-month follow-up.<br />Competing Interests: Funding Support and Author Disclosures The authors have reported that they have no relationships relevant to the contents of this paper to disclose.<br /> (Copyright © 2021 The Authors. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1876-7605
Volume :
14
Issue :
17
Database :
MEDLINE
Journal :
JACC. Cardiovascular interventions
Publication Type :
Academic Journal
Accession number :
34391704
Full Text :
https://doi.org/10.1016/j.jcin.2021.05.045