Back to Search
Start Over
Reliability of knee extensor neuromuscular structure and function and functional tests' performance.
- Source :
-
Journal of bodywork and movement therapies [J Bodyw Mov Ther] 2021 Jul; Vol. 27, pp. 584-590. Date of Electronic Publication: 2021 May 12. - Publication Year :
- 2021
-
Abstract
- Introduction: The aim of this study was to evaluate the intra and inter-rater and inter-analyzer reliability of neuromuscular variables and functional tests.<br />Methods: Cross-sectional crossover design. Two independent raters and analyzers evaluated twenty-two healthy subjects. Knee-extensor strength was assessed from three maximal voluntary isometric contractions. Muscle activation was obtained from the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) muscles. VL and RF muscles' architecture [fascicle length (FL), pennation angle (PA), muscle thickness (MT)] was obtained at rest by ultrasound. The time from five sit-to-stand (STS) trials, and the distance from the 6-min walk test (6MWT) were obtained. Intraclass correlation coefficient was determined and classified as strong (r = 0.75-1.00), moderate (r = 0.40-0.74), and weak (r < 0.40).<br />Results: Strong intra-rater reliability values were observed for strength (r = 0.97), muscle activation [VL (r = 0.91); RF (r = 0.92); VM (r = 0.80)], VL [FL (r = 0.90); PA (r = 0.94); MT (r = 0.99)] and RF [MT (r = 0.85)] muscle architecture, STS (r = 0.95), and 6MWT (r = 0.98). Inter-rater reliability also presented strong values for strength (r = 0.97), muscle activation [VL (r = 0.94); RF (r = 0.79); VM (r = 0.78)], muscle architecture VL [PA (r = 0.81) and MT (r = 0.88)] and RF [MT (r = 0.80)], STS (r = 0.93), and 6MWT (r = 0.98). A moderate correlation VL muscle architecture [FL (r = 0.69)]. Inter-analyzer muscle architecture reliability presented strong VL [FL (r = 0.77); PA (r = 0.76); MT (r = 0.91)] and RF [MT (r = 0.99)].<br />Conclusion: The high intra and inter-rater and inter-analyzer reliability values for most variables is evidence that they can be used for clinical evaluation. Muscle architecture might need a longer training period by different raters and analyzers to increase reliability.<br />Competing Interests: Declaration of competing interest The authors declare that they have no conflict of interest. The results of the study are presented clearly, honestly, and without fabrication, falsification, or inappropriate data manipulation.<br /> (Copyright © 2021 Elsevier Ltd. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1532-9283
- Volume :
- 27
- Database :
- MEDLINE
- Journal :
- Journal of bodywork and movement therapies
- Publication Type :
- Academic Journal
- Accession number :
- 34391291
- Full Text :
- https://doi.org/10.1016/j.jbmt.2021.05.004