Back to Search Start Over

Comparison of the expression of the volumetric alteration artifact in cylindrical and triangular fields of view in two cone-beam computed tomography devices.

Authors :
Cascante-Sequeira D
Coelho-Silva F
Rosado LPL
Freitas DQ
de-Azevedo-Vaz SL
Haiter-Neto F
Source :
Clinical oral investigations [Clin Oral Investig] 2022 Jan; Vol. 26 (1), pp. 1025-1033. Date of Electronic Publication: 2021 Jul 29.
Publication Year :
2022

Abstract

Objective: To compare the expression of the volumetric alteration (VA) artifact between cylindrical and convex triangular fields of view (FOVs) using high-density materials in different positions in two cone-beam computed tomography (CBCT) devices.<br />Materials and Methods: Cylinders of five high-density materials (amalgam, chromium-cobalt, gutta-percha, titanium, and zirconium) with known physical volume were individually submitted to CBCT acquisition in four positions inside a polymethylmethacrylate phantom using two different FOV shapes (convex triangular and cylindrical) on the Veraviewepocs® R100 (R100) and Veraview® X800 (X800) devices. Two oral radiologists obtained the tomographic volumes by segmenting each cylinder. The difference between the tomographic and physical volumes corresponded to the VA. These values were analyzed by intraclass correlation coefficient and analysis of variance for repeated measures with Tukey post hoc test (α = 5%).<br />Results: The FOV influenced the VA only in the X800 device (p = 0.014): the VA in the triangular FOV was greater than in the cylindrical FOV. The VA in the triangular FOV of the X800 device was greater than the R100 device (p < 0.0001). The material influenced the expression of the VA only in the R100 device (p < 0.0001); gutta-percha presented the highest VA, being underestimated, and differing from the other materials (p < 0.01).<br />Conclusion: The triangular FOV increased the VA of high-density materials in the X800 device.<br />Clinical Relevance: It is important to know if there is an influence on the volumetric alteration artifact of dental materials due to the different image formation geometry in the convex triangular FOV.<br /> (© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)

Details

Language :
English
ISSN :
1436-3771
Volume :
26
Issue :
1
Database :
MEDLINE
Journal :
Clinical oral investigations
Publication Type :
Academic Journal
Accession number :
34324084
Full Text :
https://doi.org/10.1007/s00784-021-04086-1