Back to Search Start Over

Fluoride-assisted liquid chromatography-tandem mass spectrometry method for simultaneous analysis of propofol and its metabolites without derivatization in urine.

Authors :
Lee KM
Han SM
Lee S
Jeong TY
Kim HJ
Min H
Kim KH
Cha S
Oh WK
Lee J
Source :
Journal of chromatography. A [J Chromatogr A] 2021 Aug 30; Vol. 1652, pp. 462360. Date of Electronic Publication: 2021 Jun 27.
Publication Year :
2021

Abstract

The misuse of propofol for recreational purposes has become a serious social issue. Accordingly, practical and sensitive analytical methods to investigate the chronic abuse and toxicity of propofol are required. However, current propofol determination methods using liquid chromatography-mass spectrometry (LC-MS/MS) suffer from problems associated with loss in sample preparation due to its volatility and its poor ionization efficiency and collision-induced dissociation in mass spectrometry. Herein, we have developed a sensitive and accurate fluoride-assisted LC-MS/MS method combined with direct-injection for propofol determination. Ionization via fluoride-ion attachment/induced deprotonation, effected by ammonium fluoride in the mobile phase, was found to dramatically improve the sensitivity of propofol without derivatization. Furthermore, direct injection without derivatization enables the simultaneous analysis of propofol and its phase II metabolites without analyte loss. The optimal concentration of ammonium fluoride in the mobile phase was found to be 1 mM under methanol conditions. The linearity is good (R <superscript>2</superscript>  ≥ 0.999) and the intra- and inter-day precisions for propofol determination are between 1.9 and 8.7%. The accuracies range from 87.5% to 105.4% and the limits of detection and quantitation for propofol in urine are 0.15 and 0.44 ng mL <superscript>-1</superscript> , respectively. The present method was successfully applied to human urine and showed a sufficient sensitivity to determine propofol and five phase II metabolites over 48 h in human urine after administration. Consequently, the fluoride-assisted LC-MS/MS method was demonstrated to be sensitive, accurate, and practical for the determination of propofol and its metabolites.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2021. Published by Elsevier B.V.)

Details

Language :
English
ISSN :
1873-3778
Volume :
1652
Database :
MEDLINE
Journal :
Journal of chromatography. A
Publication Type :
Academic Journal
Accession number :
34246057
Full Text :
https://doi.org/10.1016/j.chroma.2021.462360