Back to Search
Start Over
Quantifying clinical severity of physics errors in high-dose rate prostate brachytherapy using simulations.
- Source :
-
Brachytherapy [Brachytherapy] 2021 Sep-Oct; Vol. 20 (5), pp. 1062-1069. Date of Electronic Publication: 2021 Jun 27. - Publication Year :
- 2021
-
Abstract
- Purpose: To quantitatively evaluate through automated simulations the clinical significance of potential high-dose rate (HDR) prostate brachytherapy (HDRPB) physics errors selected from our internal failure-modes and effect analysis (FMEA).<br />Methods and Materials: A list of failure modes was compiled and scored independently by 8 brachytherapy physicists on a one-to-ten scale for severity (S), occurrence (O), and detectability (D), with risk priority number (RPN) = SxOxD. Variability of RPNs across observers (standard deviation/average) was calculated. Six idealized HDRPB plans were generated, and error simulations were performed: single (N = 1722) and systematic (N = 126) catheter shifts (craniocaudal; -1cm:1 cm); single catheter digitization errors (tip and connector needle-tips displaced independently in random directions; 0.1 cm:0.5 cm; N = 44,318); and swaps (two catheters swapped during digitization or connection; N = 528). The deviations due to each error in prostate D90%, urethra D20%, and rectum D1cm <superscript>3</superscript> were analyzed using two thresholds: 5-20% (possible clinical impact) and >20% (potentially reportable events).<br />Results: Twenty-nine relevant failure modes were described. Overall, RPNs ranged from 6 to 108 (average ± 1 standard deviation, 46 ± 23), with responder variability ranging from 19% to 184% (average 75% ± 30%). Potentially reportable events were observed in the simulations for systematic shifts >0.4 cm for prostate and digitization errors >0.3 cm for the urethra and >0.4 cm for rectum. Possible clinical impact was observed for catheter swaps (all organs), systematic shifts >0.2 cm for prostate and >0.4 cm for rectum, and digitization errors >0.2 cm for prostate and >0.1 cm for urethra and rectum.<br />Conclusions: A high variability in RPN scores was observed. Systematic simulations can provide insight in the severity scoring of multiple failure modes, supplementing typical FMEA approaches.<br />Competing Interests: Conflict of Interest The authors do not have conflicts of interest related to this work to disclose.<br /> (Copyright © 2021 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-1449
- Volume :
- 20
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Brachytherapy
- Publication Type :
- Academic Journal
- Accession number :
- 34193362
- Full Text :
- https://doi.org/10.1016/j.brachy.2021.05.007