Back to Search Start Over

Comparison of MRI features in lipid-rich and lipid-poor adrenal adenomas using subjective and quantitative analysis.

Authors :
Tu W
Gerson R
Abreu-Gomez J
Udare A
Mcphedran R
Schieda N
Source :
Abdominal radiology (New York) [Abdom Radiol (NY)] 2021 Oct; Vol. 46 (10), pp. 4864-4872. Date of Electronic Publication: 2021 Jun 12.
Publication Year :
2021

Abstract

Objective: To compare MR-imaging features in benign lipid-rich and lipid-poor adrenal adenomas.<br />Materials and Methods: With institutional review board approval, we compared 23 consecutive lipid-poor adenomas (chemical shift [CS] signal intensity [SI] index < 16.5%) imaged with MRI to 29 consecutive lipid-rich adenomas (CS-SI index ≥ 16.5%) imaged during the same time period. A blinded radiologist measured T2-weighted (T2W) SI ratio (adrenal adenoma/psoas muscle), dynamic enhancement wash-in (WI) and wash-out (WO) indices, and T2W texture features. Two blinded Radiologists (R1/R2) assessed T2W-SI (relative to renal cortex) and T2W heterogeneity (using 5-Point Likert scales). Comparisons were performed between groups using independent t tests and Chi-square with Holm-Bonferroni correction.<br />Results: There was no difference in age or gender between groups (p = 0.594, 0.051 respectively). Subjectively, all lipid-rich and lipid-poor adenomas were rated hypointense or isointense compared to renal cortex and T2W-SI did not differ between groups (p = 0.129, 0.124 for R1, R2). Agreement was substantial (Kappa = 0.67). There was no difference in T2W SI ratio (1.8 ± 0.9 [0.5-4.3] lipid rich versus 2.2 ± 1.0 [0.6-4.3] lipid poor, p = 0.139). Enhancement WI and WO did not differ comparing lipid-rich and lipid-poor adenomas (p = 0.759, 0.422 respectively). There was no difference comparing lipid-rich and lipid-poor adenomas T2W heterogeneity judged subjectively (p = 0.695, 0.139 for R1, R2; Kappa = 0.19) or by texture analysis (entropy, kurtosis, skewness; p = 0.134-0.191) with all adenomas except for one rated as mostly or completely homogeneous.<br />Conclusions: There is no difference in T2W signal intensity, enhancement pattern or T2W heterogeneity judged subjectively or by quantitative texture analysis comparing lipid-poor and lipid-rich adrenal adenomas.<br /> (© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)

Details

Language :
English
ISSN :
2366-0058
Volume :
46
Issue :
10
Database :
MEDLINE
Journal :
Abdominal radiology (New York)
Publication Type :
Academic Journal
Accession number :
34120206
Full Text :
https://doi.org/10.1007/s00261-021-03161-1