Back to Search Start Over

Saturation recovery-prepared magnetic resonance angiography for assessment of left atrial and esophageal anatomy.

Authors :
Siebermair J
Kholmovski EG
Sheffer D
Schroeder J
Jensen L
Kheirkhahan M
Baher AA
Ibrahim MM
Reiter T
Rassaf T
Wakili R
Marrouche NF
McGann CJ
Wilson BD
Source :
The British journal of radiology [Br J Radiol] 2021 Jul 01; Vol. 94 (1123), pp. 20210048. Date of Electronic Publication: 2021 Jun 11.
Publication Year :
2021

Abstract

Objectives: Magnetic resonance angiography (MRA) has been established as an important imaging method in cardiac ablation procedures. In pulmonary vein (PV) isolation procedures, MRA has the potential to minimize the risk of severe complications, such as atrio-esophageal fistula, by providing detailed information on esophageal position relatively to cardiac structures. However, traditional non-gated, first-pass (FP) MRA approaches have several limitations, such as long breath-holds, non-uniform signal intensity throughout the left atrium (LA), and poor esophageal visualization. The aim of this observational study was to validate a respiratory-navigated, ECG-gated (EC), saturation recovery-prepared MRA technique for simultaneous imaging of LA, LA appendage, PVs, esophagus, and adjacent anatomical structures.<br />Methods: Before PVI, 106 consecutive patients with a history of AF underwent either conventional FP-MRA ( n = 53 patients) or our new EC-MRA ( n = 53 patients). Five quality scores (QS) of LA and esophagus visibility were assessed by two experienced readers. The non-parametric Mann-Whitney U-test was used to compare QS between FP-MRA and EC-MRA groups, and linear regression was applied to assess clinical contributors to image quality.<br />Results: EC-MRA demonstrated significantly better image quality than FP-MRA in every quality category. Esophageal visibility using the new MRA technique was markedly better than with the conventional FP-MRA technique (median 3.5 [IQR 1] vs median 1.0, p < 0.001). In contrast to FP-MRA, overall image quality of EC-MRA was not influenced by heart rate.<br />Conclusion: Our ECG-gated, respiratory-navigated, saturation recovery-prepared MRA technique provides significantly better image quality and esophageal visibility than the established non-gated, breath-holding FP-MRA. Image quality of EC-MRA technique has the additional advantage of being unaffected by heart rate.<br />Advances in Knowledge: Detailed information of cardiac anatomy has the potential to minimize the risk of severe complications and improve success rates in invasive electrophysiological studies. Our novel ECG-gated, respiratory-navigated, saturation recovery-prepared MRA technique provides significantly better image quality of LA and esophageal structures than the traditional first-pass algorithm. This new MRA technique is robust to arrhythmia (tachycardic, irregular heart rates) frequently observed in AF patients.

Details

Language :
English
ISSN :
1748-880X
Volume :
94
Issue :
1123
Database :
MEDLINE
Journal :
The British journal of radiology
Publication Type :
Academic Journal
Accession number :
34111982
Full Text :
https://doi.org/10.1259/bjr.20210048