Back to Search Start Over

Inspiratory flow patterns with dry powder inhalers of low and medium flow resistance in patients with pulmonary arterial hypertension.

Authors :
Faria-Urbina M
Ung KT
Lawler L
Zisman LS
Waxman AB
Source :
Pulmonary circulation [Pulm Circ] 2021 May 13; Vol. 11 (2), pp. 20458940211012591. Date of Electronic Publication: 2021 May 13 (Print Publication: 2021).
Publication Year :
2021

Abstract

Inhalation profiles to support use of dry powder inhalers for drug delivery in patients with pulmonary arterial hypertension have not been reported. We aimed to evaluate the inspiratory flow pattern associated with low and medium flow resistance dry powder inhaler devices (RS01-L and RS01-M, respectively) in patients with pulmonary arterial hypertension. This single-center study enrolled patients with pulmonary arterial hypertension associated with connective tissue disease ( n  = 10) and idiopathic pulmonary arterial hypertension ( n  = 10) to measure the following inhalation parameters: inspiratory effort (kPa), peak inspiratory flow rate (L/min), inhaled volume (L), and flow increase rate (L/s <superscript>2</superscript> ) using the two devices. We identified a trend toward higher mean pulmonary artery pressure in the idiopathic pulmonary arterial hypertension group (50 ± 13 mmHg vs. 40 ± 11 mmHg in pulmonary arterial hypertension associated with connective tissue disease; p  = 0.077). On average, peak inspiratory flow rate was higher with RS01-L vs. RS01-M (84 ± 19.7 L/min vs. 70.4 ± 13.2 L/min; p  = 0.015). In the overall group, no differences between RS01-L and RS01-M were observed for inhaled volume, inspiratory effort, or flow increase rate. Inhaled volume with RS01-L was higher in pulmonary arterial hypertension associated with connective tissue disease vs. idiopathic pulmonary arterial hypertension patients: 1.6 ± 0.4 L vs. 1.3 ± 0.2 L; p  = 0.042. For the RS01-L, inhaled volume correlated with forced expiratory volume in one second ( r  = 0.460, p  = 0.030) and forced vital capacity ( r  = 0.507, p  = 0.015). In patients with pulmonary arterial hypertension associated with connective tissue disease using RS01-L, both inspiratory effort and flow increase rate were highly correlated with pulmonary vascular compliance ( r  = 0.903, p  = 0.0001 and r  = 0.906, p  = 0.0001; respectively); while with RS01-M, inspiratory effort was highly correlated with pulmonary vascular compliance ( r  = 0.8, p  = 0.001). Our data suggest that the use of RS01-L and RS01-M dry powder inhaler devices allowed adequate inspiratory flow in pulmonary arterial hypertension patients. The correlation between flow increase rate and pulmonary vascular compliance in pulmonary arterial hypertension associated with connective tissue disease deserves further investigation.<br />Competing Interests: Declaration of conflicting interests: The author(s) declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: Lawrence S. Zisman is employed by Gossamer Bio, Inc.<br /> (© The Author(s) 2021.)

Details

Language :
English
ISSN :
2045-8932
Volume :
11
Issue :
2
Database :
MEDLINE
Journal :
Pulmonary circulation
Publication Type :
Academic Journal
Accession number :
34035895
Full Text :
https://doi.org/10.1177/20458940211012591