Back to Search
Start Over
[Feasibility and safety of intracardiac ultrasound-assisted atrial septal puncture during radiofrequency ablation for atrial fibrillation].
- Source :
-
Zhonghua xin xue guan bing za zhi [Zhonghua Xin Xue Guan Bing Za Zhi] 2021 May 24; Vol. 49 (5), pp. 474-478. - Publication Year :
- 2021
-
Abstract
- Objective: To explore the feasibility and safety of intracardiac ultrasound-assisted atrial septal puncture (ASP) during radiofrequency ablation for atrial fibrillation. Methods: We enrolled 241 consecutive patients scheduled to radiofrequency ablation for atrial fibrillation in Beijing Anzhen Hospital from July to September 2020. Inclusion criteria: patients aged over 18 years with a clear electrocardiogram record of atrial fibrillation. Patients were divided into 2 groups: ASP with ultrasound-assisted X-ray (ultrasound group, n =123), ASP under X-ray alone (X-ray group, n =118). Clinical features of patients including age, sex, percent of paroxysmal atrial fibrillation, and repeat ablation, CHA <subscript>2</subscript> DS <subscript>2</subscript> -VASc score and past history (hypertension, diabetes mellitus, coronary artery disease, stroke/transient ischemic attack (TIA), valve diseases) and echocardiographic parameters (left atrial dimension, left ventricular ejection fraction, left ventricular end-diastolic dimension) were obtained and compared. The first-pass rate, radiation exposure time, duration of ASP, and complications of ASP were also compared between the two groups. Results: The age of patients in this cohort was (62.5±8.0) years, and the proportion of males was 57.0% ( n =138). Among them, the proportion of paroxysmal atrial fibrillation was 56.0% ( n =135), and the ratio of repeat ablation was 17.8% ( n =43). Age, sex, percent of paroxysmal atrial fibrillation, history of hypertension, diabetes mellitus were similar between the two groups. The first-pass rate was significantly higher in the ultrasound group than in the X-ray group (94.3% (116/123) vs. 79.7% (94/118), P =0.001); the exposure time of X-ray was significantly shorter in the ultrasound group than in the X-ray group ((31.3±7.9) s vs. (124.8±35.7) s, P <0.001), while the duration of ASP was longer in the ultrasound group ((10.1±1.8) minutes vs. (8.2±1.3) minutes, P <0.001). In terms of complications, the incidence of puncture into the pericardium was lower in the ultrasound group (0 vs.3.4% (4/118), P =0.039); the rate of transient ST-segment elevation post ASP was similar between the ultrasound group and X-ray group (2.4% (3/123) vs. 1.7% (2/118), P =0.999). Conclusion: Intracardiac ultrasound-assisted atrial septal puncture can effectively improve the accuracy of atrial septal puncture, shorten the radiation exposure time, and reduce the complications related to atrial septal puncture.
Details
- Language :
- Chinese
- ISSN :
- 0253-3758
- Volume :
- 49
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Zhonghua xin xue guan bing za zhi
- Publication Type :
- Academic Journal
- Accession number :
- 34034381
- Full Text :
- https://doi.org/10.3760/cma.j.cn112148-20210113-00039