Back to Search Start Over

Acute Toxicity in Hypofractionated/Stereotactic Prostate Radiotherapy of Elderly Patients: Use of the Image-guided Radio Therapy (IGRT) Clarity System.

Authors :
DI Franco R
Borzillo V
Alberti D
Ametrano G
Petito A
Coppolaro A
Tarantino I
Rossetti S
Pignata S
Iovane G
PerdonĂ  S
Quarto G
Grimaldi G
Izzo A
Castaldo L
Muscariello R
Serra M
Facchini G
Muto P
Source :
In vivo (Athens, Greece) [In Vivo] 2021 May-Jun; Vol. 35 (3), pp. 1849-1856.
Publication Year :
2021

Abstract

Background: The use of intra-fractional monitoring and correction of prostate position with the Image Guided Radio Therapy (IGRT) system can increase the spatial accuracy of dose delivery. Clarity is a system used for intrafraction prostate-motion management, it provides a real-time visualization of prostate with a transperineal ultrasound. The aim of this study was to evaluate the use of Clarity-IGRT on proper intrafraction alignment and monitoring, its impact on Planning Tumor Volume margin and on urinary and rectal toxicity in elderly patients not eligible for surgery.<br />Patients and Methods: Twenty-five elderly prostate cancer patients, median age=75 years (range=75-90 years) were treated with Volumetric Radiotherapy and Clarity-IGRT using 3 different schemes: A) 64.5/72 Gray (Gy) in 30 fractions on prostate and seminal vesicles (6 patients); B) 35 Gy in 5 fractions on prostate and seminal vesicles (12 patients); C): 35 Gy in 5 fractions on prostate (7 patients). Ultrasound identification of the overlapped structures to the detected ones during simulation has been used in each session. A specific software calculates direction and entity of necessary shift to obtain the perfect match. The average misalignment in the three-dimensional space has been determined and shown in a box-plot.<br />Results: All patients completed treatment with mild-moderate toxicity. During treatment, genitourinary toxicity was 32% Grade 1; 4% Grade 2, rectal was 4% Grade 1. At follow-up of 3 months, genitourinary toxicity was 20% Grade 1; 4% Grade 2, rectal toxicity was 4% Grade 2. At follow-up of 6 months, genitourinary toxicity was 4% Grade 1; 4% Grade 2. Rectal toxicity was 4% Grade 2.<br />Conclusion: Radiotherapy with the Clarity System allows a reduction of PTV margins, the amount of fractions can be reduced increasing the total dose, not exacerbating urinary and rectal toxicity with greater patient's compliance.<br /> (Copyright© 2021, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.)

Details

Language :
English
ISSN :
1791-7549
Volume :
35
Issue :
3
Database :
MEDLINE
Journal :
In vivo (Athens, Greece)
Publication Type :
Academic Journal
Accession number :
33910872
Full Text :
https://doi.org/10.21873/invivo.12447