Back to Search Start Over

Staple-line reinforcement using barbed sutures in 1008 sleeve gastrectomies.

Authors :
Özgen G
Çalıkoğlu İ
Acunaş B
Yerdel MA
Source :
Langenbeck's archives of surgery [Langenbecks Arch Surg] 2021 Aug; Vol. 406 (5), pp. 1683-1690. Date of Electronic Publication: 2021 Apr 07.
Publication Year :
2021

Abstract

Purpose: Among various staple-line reinforcement methods applied during sleeve gastrectomy (SG), although data on full-thickness-continuous-suturing (FTCS) is nearly nil, it has been considered as potentially harmful. The safety/efficacy profile of FTCS is assessed.<br />Methods: All consecutive SGs completing 3-month follow-up were studied. Data on peri-operative parameters, complications, and follow-up were prospectively recorded. All reinforcements were completed by FTCS utilizing barbed suture. Super-super obese, secondary SGs, SGs performed in patients with prior anti-reflux surgery, and SGs performed with additional concomitant procedures were evaluated as "technically demanding" SGs. Student's t/chi-square tests were used as appropriate.<br />Results: Between January 2012 and July 2020, 1008 SGs (941 "primary-standard," 67 "technically demanding") were performed without mortality/venous event. Single leak occurred in a patient with sleeve obstruction (0.1%). Thirteen bleedings, 4 requiring re-surgery (0.4%), and 17 stenoses (1.7%) were encountered. Four stenoses were treated with gastric bypass (1 emergency), 6 by dilatation(s), and one required parenteral nutrition. Six patients with stenosis chose not to have any treatment. No statistically significant difference was observed in postoperative complications between "primary-standard" and "technically demanding" SGs (p > 0.05). The median follow-up was 44 months. The excess weight loss % at 5th year was 80.1%. Suturing added 28.4 ± 6 minutes to the SG, 3 or fewer sutures were used to complete the reinforcement in > 95%. No mishap/complication occurred related to suturing.<br />Conclusion: FTCS produced excellent result in terms of leakage/hemorrhage with an acceptable stenosis rate at a low cost with half-an-hour increase in the operating time. In contrast to previous allegations, no harm attributable to stitching itself occurred.<br /> (© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)

Details

Language :
English
ISSN :
1435-2451
Volume :
406
Issue :
5
Database :
MEDLINE
Journal :
Langenbeck's archives of surgery
Publication Type :
Academic Journal
Accession number :
33829311
Full Text :
https://doi.org/10.1007/s00423-021-02161-5