Back to Search Start Over

Impact of an automated multiple emitter whole-room ultraviolet-C disinfection system on hospital acquired infections: A quasi-experimental study.

Authors :
Steele M
Hurtado RR
Rychlik K
Bonebrake A
Bovee MC
O'Donnell A
Perryman J
Kociolek LK
Source :
American journal of infection control [Am J Infect Control] 2021 Sep; Vol. 49 (9), pp. 1200-1203. Date of Electronic Publication: 2021 Mar 24.
Publication Year :
2021

Abstract

A quasi-experimental study performed in a pediatric hematology-oncology unit demonstrated that whole-room ultraviolet-C disinfection was associated with a significant reduction in hospital-onset Clostridioides difficile infection (P< .01, trend and level), but not healthcare-associated viral respiratory infections (P= .06 for trend, P= .36 for level) or central line-associated bloodstream infections (P> 0.75, trend and level).<br /> (Copyright © 2021. Published by Elsevier Inc.)

Details

Language :
English
ISSN :
1527-3296
Volume :
49
Issue :
9
Database :
MEDLINE
Journal :
American journal of infection control
Publication Type :
Academic Journal
Accession number :
33774103
Full Text :
https://doi.org/10.1016/j.ajic.2021.03.009