Back to Search Start Over

Determination of selected water-soluble vitamins (thiamine, riboflavin, nicotinamide and pyridoxine) from a food matrix using hydrophilic interaction liquid chromatography coupled with mass spectroscopy.

Authors :
Porter K
Lodge JK
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2021 May 01; Vol. 1171, pp. 122541. Date of Electronic Publication: 2021 Jan 12.
Publication Year :
2021

Abstract

Water-soluble vitamins are essential dietary components with a multitude of important functions that require quantification from food sources to characterise the nutritional status of food. In this study, we have developed a hydrophilic interaction chromatography (HILIC) based method coupled to single-quadrupole mass spectrometry (MS) for the analysis of selected water-soluble vitamins. Due to their involvement in energy release from macronutrients, the quantification of thiamine (B <subscript>1</subscript> ), riboflavin (B <subscript>2</subscript> ), nicotinamide (B <subscript>3</subscript> ) and pyridoxine (B <subscript>6</subscript> ) offers significant value in food analysis. A commercially available vegetable soup was selected as the food matrix for this study and utilised to develop an efficient extraction procedure for the vitamins of interest. Vitamins were extracted using meta-phosphoric acid coupled with a reducing agent, DL-dithiothreitol (DTT) to produce the parent compound. The extracted vitamins were then analysed using an LC-MS system with electrospray - atmospheric pressure ionization (ES-API) source, operated in positive single ion monitoring (SIM) mode. The MS provided good linearity within the investigated range from 5 to 400 ng/mL with coefficient of determination (r <superscript>2</superscript> ) ranging from 0.98 to 0.99. Retention times (0.65-9.04 min) were reproducible and no coelution between vitamins was observed. Limit of detection (LOD) varied from 2.4 to 9.0 ng/mL and limit of quantification (LOQ) was from 8 to 30 ng/mL, comparable to previously published studies. The extraction method provided good intra-day (%CV 1.56-6.56) and inter-day precision (%CV 8.07-10.97). Standard injections were used as part of quality control measures and provided excellent reproducibility (%CV 0.9-3.4). The overall runtime of this method was 19 min, including column reconditioning. Using this method, the quantity of thiamine (67 ± 7 ng/g), riboflavin (423 ± 39 ng/g), nicotinamide (856 ± 77 ng/g) and pyridoxine (133 ± 11 ng/g) was determined from a complex food matrix. In conclusion, we have developed a rapid and reliable, HILIC-single quad MS method utilising SIM for the low-level quantification of four B vitamins in a vegetable soup matrix in under 20 min. This method has shown excellent linearity, intra- and inter-day reproducibility and is directly applicable to other plant-based food matrices.<br /> (Copyright © 2021. Published by Elsevier B.V.)

Details

Language :
English
ISSN :
1873-376X
Volume :
1171
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
33773258
Full Text :
https://doi.org/10.1016/j.jchromb.2021.122541