Back to Search
Start Over
Acute Budd Chiari syndrome in an ECMO patient.
- Source :
-
Perfusion [Perfusion] 2022 Jul; Vol. 37 (5), pp. 530-532. Date of Electronic Publication: 2021 Mar 26. - Publication Year :
- 2022
-
Abstract
- Introduction: Point-of-care ultrasound (POCUS) is widely utilized to make timely decisions regarding patient care. This approach allowed us to diagnose the cause of acutely rising transaminases in a patient in severe ARDS secondary to influenza pneumonia requiring veno-venous extracorporeal membrane oxygenation (VV-ECMO).<br />Case Report: A 36-year-old female presented with acute hypoxemic respiratory failure secondary to influenza A infection. Within 24 hours, she required intubation and met severe ARDS criteria with a PaO <subscript>2</subscript> /FiO <subscript>2</subscript> ratio of 62. She was managed with high PEEP and low tidal volume ventilation strategy, however her clinical status continued to deteriorate and the decision was made to pursue VV-ECMO. Within hours of cannulation her aspartate aminotransferase (AST) dramatically increased from 736 to 4512 µ/L, with concurrent mild increases in alanine aminotransferase (ALT) and creatine phosphokinase (CPK). Point-of-care ultrasound was performed which revealed a complete absence of flow in the hepatic vein, secondary to acute obstruction by an 25-French drainage catheter for the ECMO circuit. The catheter was exchanged with a smaller French catheter and the patient's transaminases and CPK levels quickly decreased and returned to normal within several days.<br />Discussion: Budd-Chiari syndrome (BCS) is a rare but potentially life-threatening condition caused by acute obstruction of hepatic vein blood flow that can lead to fulminant liver failure if left untreated. BCS is usually caused by a hepatic vein thrombus, however any mechanical obstruction can lead to the same pathology. Point-of-care ultrasound lead to a prompt diagnosis and allowed for quick action to correct the obstruction. Although BCS is not a common problem with VV-ECMO, the syndrome should always be on the differential of any patient on VV-ECMO with acutely rising transaminases.<br />Conclusion: Ultrasound played an integral role in providing a crucial diagnosis of BCS secondary to obstruction by an ECMO drainage catheter.
Details
- Language :
- English
- ISSN :
- 1477-111X
- Volume :
- 37
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Perfusion
- Publication Type :
- Academic Journal
- Accession number :
- 33769103
- Full Text :
- https://doi.org/10.1177/02676591211003874